Error Diagnosis
6.1
Problems When Using Modules from Other
Manufacturers
Error Display
The PC crashes during power up.
Cause
The following causes are possible:
– Double assignment of I/O addresses
– Double assignment of hardware interrupts and/or DMA channels
– Signal frequencies or signal levels are not met
– Different connector assignments
– "Reset Configuration" was not carried out.
Remedy
Check your computer configuration:
• If the computer configuration is the same as when your PC was delivered,
please contact your technical support team.
• If the computer configuration has changed, reestablish the configuration you
had when your PC was delivered. Remove any modules from other
manufacturers. Perform a complete restart on your PC.
– If the PC still crashes, you must contact your technical support team.
– If the error no longer occurs, the module you used from another
manufacturer was the cause of the fault. Replace this module with a
Siemens module, or contact the module supplier.
• Force "Reset Configuration" via BIOS Setup (see Manual "BIOS Setup" on the
CD supplied "Rack PC IL 40 S Documentation and Drivers".