Bahco IZO-D User Manual page 8

Hide thumbs Also See for IZO-D:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
MEMORY FUNCTIONS (OPTIONAL)
The IZO-DM/DFM/DRM wrench will store, recall and download data to a
compu ter or printer via RS232 true standard. A download software disk is
included with the wrench for use with a PC running WINDOWS or NT
opera ting system. Refer to the BAHCO disk for PC installation instructions.
Refer to your serial printer instruction manual for installation instructions –
see Setup serial baud rate.
Two Excel templates are provided on your BAHCO disk for your conve -
nience. Copy them to your hard drive, rename them, and make whatever
changes suit your needs. Note: BAHCO does not provide technical support
for these templates.
Use the DOWNLOAD Template to print the previously stored data list from
the wrench. The PRINT function of the wrench sends out the number of the
reading, the torque value and the units of measure. Use DATE-TIME
Template to automatically create a DATE and TIME stamp for each reading,
while the wrench is connected to the computer. Individual readings are both
stored in the wrench and are sent out the serial port simultaneously. Only the
torque value and the units of measure are sent out during the store function.
Store
Momentarily push the
the flashing display. The audible alert will sound once and reading will be
stored and numbered in memory, and the reading will be sent out the RS232
port simultaneously.
The "M" indicator will turn on when at least one reading is stored in memory.
Recall
To review the data in memory, push and hold the
seconds. The last reading will be displayed alternating with its memory
location number. Use the
scroll through the data list.
Push
ON/ZERO key to return to measurement mode.
Clear
To clear a reading, enter the RECALL mode as above. Scroll to the memory
location number that you want to clear and hold the
three seconds. The display will show "CLr" for one second and decrement to
the next reading. If this was not the last reading stored, all subsequent
readings will shift down one memory location.
Push
ON/ZERO key to return to measurement mode.
Clear all
To clear the entire data list, enter the RECALL mode as above.
Hold the
MEMORY key and the
three seconds. The "M" indicator will turn off and the wrench will revert to
measurement mode.
Print
To send the entire data list out the RS232 port, push the
momentarily. The audible alert will sound twice and the display will read
"SEnd" until the data stream is finished.
The wrench will then revert to measurement mode.
8
MEMORY key to store PEAK readings captured on
INCREMENT and
INCREMENT key simultaneously for
MEMORY key for three
DECREMENT keys to
MEMORY key for
PRINT key