WARNING DEVICE LAL-SRW3
Installation
3.1.1
EN
12 - EN
Mounting the NVF-104/34-PF Overflow Sensor
Usually, the sensor is mounted with the lower edge a few centimeters above the
normal liquid level (water zero line) in a position so close to the water zero line that
the switching point is surrounded by liquid when an overflow occurs. This occurs
if the coalescence filter is dirty,
if the automatic closure device is blocked, or
if another situation causes the oily liquid to overflow or become contaminated.
The switching point is at the same level as the 5 mm hole on the side of the
sensor.
1
A
B
C
Figure 3.2
Mounting the overflow sensor
1
Overflow sensor NVF-104/34-PF
A
Air
B
Oil
C
Water
L
Water zero line
S
Sensor switching point
X
Alarm limit (maximum liquid level)
S