Hypertherm Powermax65 Field Service Bulletin page 8

Machine interface cable with voltage divider board
Hide thumbs Also See for Powermax65:

Advertisement

Available languages

Available languages

Machine interface cable with Voltage DiViDer boarD
Loosen the front panel of the power supply
To provide easy access for connecting the interface cables to the power board:
1. Remove the metal strap from the top of the power supply by lifting the strap straight up. The strap holds the two
end panels together.
2. Carefully place the power supply onto the fan side to access the bottom screws.
3. Remove the two screws that hold the front panel to the bottom of the power supply.
4. Using a blade screwdriver, carefully pry the front panel off the bottom of the power supply.
5. Position the power supply upright.
6. Carefully pull the front panel away from the body of the power supply. The front panel is still attached to the power
supply body and can only move a short distance.