Service manual
11.3.1.4 Open or short circuit of temperature sensor.
Measure the resistance value
of the sensor via Appendix 1
11.3.1.5 Full-water malfunction
42
Check the connections
between temperature
sensor and PCB. Are the
connections good?
Yes
Is it normal?
Yes
Replace the indoor PCB
No
Correct the connections.
No
Replace the sensor.
DM16-01.01.11-01en