Midea M2OE-14HFN1-Q Service Manual page 30

Super dc inverter multi type
Table of Contents

Advertisement

Service manual
3
A indoor unit capacity
4
B indoor unit capacity
5
C indoor unit capacity
6
D indoor unit capacity
7
E indoor unit capacity
8
A Indoor unit capacity demand code
9
B Indoor unit capacity demand code
10
C Indoor unit capacity demand code
11
D Indoor unit capacity demand code
12
E Indoor unit capacity demand code
13
Total indoor units amendatory capacity
demand code
14
The frequency corresponding to the total
indoor units amendatory capacity demand
15
The frequency after the frequency limit
16
The frequency sending to compressor
control chip
17
A indoor unit evaporator outlet temp.(T
18
B indoor unit evaporator outlet temp.(T
19
C indoor unit evaporator outlet temp.(T
20
D indoor unit evaporator outlet temp.(T
21
E indoor unit evaporator outlet temp.(T
22
A indoor unit room temp.(T
23
B indoor unit room temp.(T
24
C indoor unit room temp.(T
25
D indoor unit room temp.(T
26
E indoor unit room temp.(T
27
A indoor unit evaporator temp.(T
28
B indoor unit evaporator temp.(T
29
C indoor unit evaporator temp.(T
30
D indoor unit evaporator temp.(T
31
E indoor unit evaporator temp.(T
32
Condenser pipe temp.(T3)
33
Outdoor ambient temp.(T4)
34
Compressor discharge temp.(T5)
35
AD value of current
36
AD value of voltage
37
EXV open angle for A indoor unit
38
EXV open angle for B indoor unit
39
EXV open angle for C indoor unit
40
EXV open angle for D indoor unit
41
EXV open angle for E indoor unit
42
Frequency limit symbol
30
The capacity unit is horse power. If the indoor unit is not connected,
the digital display tube will show: "――"
(7K:0.8HP, 9K:1HP,12K:1.2HP,18K:1.5HP)
Norm value*HP
(7K:0.8HP, 9K:1HP,12K:1.2HP,18K:1.5HP)
A)
2B
B)
If the temp. is lower than -9 degree, the digital display tube will show
2B
"-9".If the temp. is higher than 70 degree, the digital display tube will
C)
2B
show "70". If the indoor unit is not connected, the digital display tube
D)
will show: "――"
2B
E)
2B
A)
If the temp. is lower than 0 degree, the digital display tube will show
1
"0".If the temp. is higher than 70 degree, the digital display tube will
B)
1
show "70". If the indoor unit is not connected, the digital display tube
C)
will show: "――"
1
D)
1
E)
1
A)
2
B)
2
C)
If the temp. is lower than -9 degree, the digital display tube will show
2
"-9".If the temp. is higher than 70 degree, the digital display tube will
D)
2
show "70". If the indoor unit is not connected, the digital display tube
E)
will show: "――"
2
The display value is between 30~129 degree. If the temp. is lower
than 30 degree, the digital display tube will show "30".If the temp. is
higher than 99 degree, the digital display tube will show single digit
and tens digit. For example, the digital display tube show "0.5",it
means the compressor discharge temp. is 105 degree.)
The display value is hex number.
For example ,the digital display tube show "Cd", it means AD value is
205.
Actual data/4.
If the value is higher than 99, the digital display tube will show single
digit and tens digit.
For example ,the digital display tube show "2.0",it means the EXV
open angle is 120×4=480p.)
Bit7
Bit6
Bit5
Frequency limit caused by IGBT
radiator
Frequency limit caused by PFC
Frequency limit caused by T4.
Multi DC inverter R410A. Outdoor unit
DM16-01.01.11-01en
The display value
is hex number. For
example, the
digital display tube
show 2A,then