Configuration Procedure Of Module; Notes For Aux; Operating Mode - Ebyte E30-433T20S3 User Manual

Smd serial port wireless module
Hide thumbs Also See for E30-433T20S3:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.

5.6.3 Configuration procedure of module

Only happened when power-on resetting or exiting sleep mode

5.6.4 Notes for AUX

No.
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means if it
1
meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX outputs
high level.
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms since AUX
2
outputs high level, the mode switch will be completed.
After switching to new operating mode, it will not work in the new mode immediately until AUX rising edge lasts for 2ms . If
3
AUX stays on the high level, the operating mode switch can be effected immediately.
When the user switches to other operating modes from mode 3 (sleep mode) or it's still in reset process, the module will reset
4
user parameters, during which AUX outputs low level.

6. Operating mode

There are four operating modes, which are set by M1 and M0, the details are as follows:
Mode(0-3)
M1
0 Normal mode
0
1 Wake-up
0
2 Power-saving Mode
1
3 sleep mode
1
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd.
M0
UART and wireless channel are open, transparent transmission
0
is on
UART and wireless channel are open. The difference between
normal
mode and wake-up mode is that it will add preamble code
1
automatically before data packet transmission so that it can
awaken
the receiver works in mode 2
Users can access the register through the serial port to control
0
the working state of the module
1
Parameter setting
Description
Description
E30-433T20S3 User manual
Remark
The receiver must work in
mode 0 or mode 1
The receiver can work in
mode 0, mode 1 or mode 2
1. The transmitter must
work in mode 1
2. Transmitting is not
allowed in this mode
More in working parameter
8

Advertisement

Table of Contents
loading

Table of Contents