7] FAULT FINDING

PROBLEM
Door locking
The lock is not receiving DC current.
impossible
The lock and the armature are not
lined up with each other.
Holding
force
reduced
Low voltage or armature jammed.
Faulty reed
Voltage too low. Misalignment.
switch
8] LIMITED LIFETIME WARRANTY [EXTRACT]*
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed
in accordance with the manufacturer's instructions and has not been modifi ed or tampered with. Only product
recognized by CDVI to be defective should be returned under these warranty terms if accompanied
by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair
or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty
does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only if the
product is registered, within 1 month from delivery to the fi nal costumer. To obtain full details of this warranty
and to register the product to commence the "Limited Lifetime Warranty", complete the enclosed registration
card and return it, either by e-mail or post, to the relevant CDVI address or completion of the on line
registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive remedy.
CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or malfunction
of, its product. In no event the entire liability can not exceed the purchase price of the product. The CDVI
local country contact details can be found on line by visiting www.cdvigroup.com or on the back cover
of the installation manual.
DISCLAIMER OF WARRANTY: EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER
EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS,
THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
POSSIBLE CAUSE
- Check that the wires are connected to the right terminals.
- Check that the power supply is compatible.
- Check that the lock is connected to the circuit correctly.
- Check that the lock is connected to the circuit correctly.
- Check that the electromagnet and the armature
are properly aligned.
- Check that the contact faces are free from dirt and rust.
- Check that the armature is soft mounted.
- Check that the lock is receiving the correct power supply
satisfactorily.
- check the tightening of the armature and the condition
of the rubber.
- Check the power supply.
- Cable cross section to be determined according to the power
supply and the locking.
- e.g.: 2 x 1.5mm2 ≥ 10m.
* Refer to complete limited lifetime warranty on cdvigroup website.