500kg mortice electromagnetic lock stainless steel
Hide thumbs Also See for I500ER:

Advertisement

Available languages

Available languages

Quick Links

PRODUCT PRESENTATION
NFS 61-937
Monitored
Mortice
High corrosion resistance
Delivered with armature plate
No mechanical wear
Ease of installation
Recommended for exterior use
Fail safe (Door unlocked when power off)
Holding force : 500 kg
Built-in varistor : Built-in electronic protection to
eliminate back EMF
Dimensions (L x W x D): 228.5 x 64 x 37.5 mm
Armature plate dimensions (L x W x D): 185 x 60 x 12 mm
Power supply: 12/24V dc
Consumption: 500 mA with 12V dc
250 mA with 24V dc
IP42
DEEE & RoHS
PACKAGE CONTENT
Magnetic
Armature
lock
plate
1 1
1 1
M8x35
M8x25
Screw
Screw
1 1
1 1
ELECTRICAL CONNECTIONS
12V dc default setup
Terminal
Correspondence
block
+
12 or 24V dc
-
0V
N.C
NC (Normally closed)
COM
COM
N.O
NO (Normally open)
The NO/NC signal only switches when
the door is closed with the power to it on.
IMPORTANT NOTE
- Check the jumper position before connecting
the lock to the input current. A wrong position
could damage the lock. This type of damage
is not covered by the warranty.
- Make sure that the magnet and the armature
meet evenly over their entire mating surfaces.
The Armature plate must be able to pivot
slightly around its center mounting screw
to compensate for any door misalignment.
CDVI FRANCE + EXPORT
CDVI UK
31, av. du Général Leclerc
[UNITED KINGDOM - IRE-
93500 PANTIN - France
LAND]
Phone +33 (0)1 48 91 01 02
Phone +44 (0)1628 531300
www.cdvi.com
www.cdvi.co.uk
CDVI SWEDEN
CDVI AMERICAS
[SWEDEN - DENMARK -
[CANADA - USA]
NORWAY FINLAND]
Phone +1 (450) 682 7945
Phone +46 (0)31 760 19 30
www.cdvi.ca
www.cdvi.se
Manufacturing Access Control since 1985
I500ER
500kg Mortice Electromagnetic lock
Stainless steel
10
YEAR
WARRANTY
Certification CE
5x16
M5X8
Steel washer
Roll pin
Srew
2 2
8 8
Cap nut
Bracket
Manual
1 1
1 1
Voltage selection jumpers
12V dc
Recommended power supplies
Voltage
Voltage
12V dc
24V dc
24V dc
CDVI BENELUX
[BELGIUM - NETHERLAND -
LUXEMBOURG]
Phone +32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI SUISSE
Phone +41 (0)21 882 18 41
www.cdvi.ch
Maglock
Maglock
M8 screw
M8 screw
Armature plate
Armature plate
Roll pin
Roll pin
Rubber washer
Rubber washer
Steel washer
Steel washer
Cap nut
Cap nut
Rubber
washer
2 2
1 1
1 1
24V dc
ADC335
ADC612S
ADC324
ADC624S
CDVI IBÉRICA
[SPAIN - PORTUGAL]
Phone +34 (0)935 390 966
www.cdviberica.com
CDVI ITALIA
Phone +39 0321 90 573
Fax: +39 0321 90 8018
www.cdvi.it
MOUNTING RECOMMENDATIONS
Armature plate
- It is vital that the magnetic lock and armature
plate are securely fixed to their supports.
- The magnetic lock and the armature plate must
be aligned.
- The armature plate must be mounted "floating"
around the central mounting screw to
compensate for any misalignment of the door
OPTIONAL ACCESSORIES
AMCCHANFR16
References
AMCHHANFR20
Armature mounting
Armature mounting
Description
Description
plate
plate
CDVI TAIWAN
CDVI POLSKA
Phone +886 (0)42471 2188
Phone +48 12 659 23 44
www.cdvichina.cn
www.cdvi.com.pl
CDVI CHINA
CDVI GERMANY
Phone +86 10 84606132/82
+49 (0) 175 2932 901
www.cdvichina.cn
www.cdvi.de
CDVI MAROC
www.cdvi.com
Phone +212 5 2248 0940
www.cdvi.ma
EN
M5 screw
M5 screw
Bracket
Bracket

Advertisement

loading

Summary of Contents for CDVI I500ER

  • Page 1 24V dc 24V dc ADC324 ADC624S to compensate for any door misalignment. CDVI TAIWAN CDVI FRANCE + EXPORT CDVI UK CDVI BENELUX CDVI IBÉRICA CDVI POLSKA Phone +886 (0)42471 2188 Phone +48 12 659 23 44 31, av.
  • Page 2 24V DC 24V DC ADC324 ADC624S compenser un mauvais alignement de la porte. CDVI FRANCE + EXPORT CDVI UK CDVI BENELUX CDVI IBÉRICA CDVI TAIWAN CDVI POLSKA 31, av. du Général Leclerc...