Kampmann 30515 Assembly And Installation Instructions Manual

Kampmann 30515 Assembly And Installation Instructions Manual

Electronic speed controller

Advertisement

Quick Links

Kampmann.de/installation_manuals
I525/02/17 EN SAP No. 1248327
Electronic speed controller
recirculating air with digital timer and room
temperature control type 30515
Assembly and installation instructions
Keep these instructions in a safe place for future use!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30515 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kampmann 30515

  • Page 1 Electronic speed controller recirculating air with digital timer and room temperature control type 30515 Assembly and installation instructions Keep these instructions in a safe place for future use! Kampmann.de/installation_manuals I525/02/17 EN SAP No. 1248327...
  • Page 2: Table Of Contents

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions Key to symbols: Contents Caution! Danger! 1. Intended use ................3 Non-compliance with this 2. Safety information ..............4 information can lead to serious personal injuries or damage to 3.
  • Page 3: Intended Use

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 1. Intended use The Kampmann electronic speed controller type 0-10 V, type 30515 has been designed in compliance with the state of the art and recognised safety regulations.
  • Page 4: Safety Information

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 2. Safety information This electronic continuously variable speed controller 0-10 V type 30515 has been developed and produced in accordance with the state of the art and current statutory standards and guidelines.
  • Page 5: Assembly And Installation

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 3. Assembly and installation Assembly of the control • Disconnect all parts of the system that are worked on and prevent from unauthorised reconnection! •...
  • Page 6: Cabling

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 3.1 Cabling General information • Lay all low voltage cables along the shortest route (room temperature sensor, digital inputs).
  • Page 7 Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions Fig. 4: Cabling diagram...
  • Page 8: Electrical Wiring

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 3.4 Electrical wiring Safety information The wiring of this product requires expert knowledge of electrical engineering. This knowledge, generally learned in vocational training in the field stated, is not described separately here.
  • Page 9: Information Can Lead To Serious 3.5 Inputs And Outputs

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 3.5 Inputs and outputs Digital inputs External release Release Input DI1 GND closed no activation Input DI1 GND open...
  • Page 10: Function And Settings

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 4. Function and settings 4.1. DIP switch DIP 1 Digital input 1 and 2 (DI1, DI2) Potential-free N/O (factory setting)
  • Page 11: Room Cooling Down Prevention

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 4.3 Room cooling down prevention The room cooling down function is superior to all operating modes and works independently of the external enable contact. The feature is enabled using the “OFF”...
  • Page 12: Operation

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5. Operation 1 Digital timer 2 Indicator light 3 Day temperature setting 4 Night temperature setting 5 Speed controller...
  • Page 13 Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions ARRÊT Unit switched off or Appareil arrêté no voltage connected ou absence de courant Green – light permanently on, Lumière continue verte,...
  • Page 14 1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5 and 6 Speed controller and operating mode selector switch Speed controller Function Off* Manual Auto Operating Speed depending on the deviation of the...
  • Page 15: Operation Of The Timer

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.1 Operation of the timer Safety information A fault on the timer needs to be repaired and inspected by a specialist.
  • Page 16: To Pass These Instructions On 5.4 Program Structure

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.4 Program structure Reset (initial installation) Read/Set Menu Set time, 24-hour or AM/PM format 24-hour blinks, use +/- to select, then OK...
  • Page 17: Setting The Timer

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.5 Setting the timer The procedure for programming the timer depends on whether the default and individual programs are to be used. The procedure is different for each.
  • Page 18: Setting The Time Format, Time, Day Of The Week

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.6 Setting the time format, time, day of the week • First, select the programming procedure, i.e. Reset or Menu mode...
  • Page 19: End Users Or Operators. Retain 5.7 Default Programs

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.7 Default programs Programs P01-03: The on and off times for programs P01 to P03 are pre-set (PRE). The user can change these programs.
  • Page 20: Individual Programs

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.8 Individual programs Procedure after entering the time and day in Menu mode or after adding programs to the default programs P01 to P03: Setting program ON •...
  • Page 21 Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions Setting hours OFF • Select the hour (+/-) and confirm with OK. Setting minutes OFF • Select the minutes (+/-) and confirm with OK.
  • Page 22: Deleting Programs

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.9 Deleting programs • First, press the Menu key and then OK until the program’s ON switch- ing time to be deleted appears.
  • Page 23: Technical Data For Timer

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 5.12 Technical data for timer Dimensions W x H x D 32.4 x 41.6 x 14.9 mm Installation depth 12 mm Approx.
  • Page 24 1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions Before commissioning, undertake the following: • Are all the components connected properly as per the wiring diagrams? • Is the protective conductor (PE) connected properly on all components? •...
  • Page 25 Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions Inspections during ongoing operation • Check that the fault signal contacts of the connected motors are working correctly by disconnecting one of the wires on terminals Err/GND in the controller.
  • Page 26: Operating Fault

    1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions • Then re-connect the wire. • Rectify the fault and return the system to its original operating mode. • Check the room temperature control (PI controller). To do this, turn the speed controller to "Auto", the operating mode selector switch to...
  • Page 27: Technical Data

    Electronic continuously variable speed controller 1.96 recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions 8. Technical data Nominal voltage 100 - 240 V +/- 10% Max. fuse Max. total nominal current for unit heaters and valve actuators Max.
  • Page 28 1.96 Electronic continuously variable speed controller recirculating air with digital timer and room temperature control, type 30515 Assembly and installation instructions...
  • Page 30 Kampmann.eu Kampmann.co.uk Kampmann GmbH Kampmann UK Ltd. Friedrich-Ebert-Str. 128 - 130 Dial House, Govett Avenue 49811 Lingen (Ems) Shepperton, Middlesex, TW17 8AG Germany Great Britain +49 591 7108-660 +44 (0)1932 228592 +49 591 7108-173 +44 (0)1932 228949 export@kampmann.de info@kampmann.co.uk Kampmann.eu...