Operating instructions
Safety-monitoring module

8 Appendix

8.1 Wiring examples
The application examples shown are suggestions. They however do
not release the user from carefully checking whether the switchgear
and its set-up are suitable for the individual application.
The wiring diagram is shown with guard doors closed and in a de-
energised condition. Inductive loads (e.g. contactors, relays, etc.)
are to be provided with suitable interference suppression circuitry.
Do not connect additional loads to terminal S..
AES 2355/2356/2555/2556
Monitoring of safety guards by means of magnetic safety sensors (BNS)
Contacts 43/44 and 51/55 not available for AES 2355 / 2356
24...230V AC/DC
A1
A1
S13
S14
S21
S22
X1
S1
100mA
max.
2555
2556
S2
A2
A2
S13
S14
S21
S22
X7
24... 2 30V AC/DC
AES 2365 / 2365
Monitoring of two independent safety guards by means of magnetic
safety sensors (BNS)
24. . . 2 30V AC/DC
A1
A1
S13
S14
S21
S22
X1
S1
100mA
max.
S2
A2
A2
S13
S14
S21
S22
X7
AES 2365/2366
24. . .230V AC/DC
4
GND
L1
X2
Y1
Y2
13
23
33
43
51
K1
K2
X8
GND PE
14
24
34
44
52
K3
K4
N
M
3
GND
L1
S
X2
Y1
Y2
13
23
33
K1
K2
X8
GND
PE
14
24
34
K3
K4
N
M
3
AES 2355/2356; AES 2555/2556
AES 2365/2366; AES 2565/2566
AES 2565 / 2566
24...230V AC/DC
A1
A1
S13
S14
S21
S22
S1
100mA
max.
S2
A2
A2
S13
S14
S21
S22
24...230V AC/DC
Legend
A
Positive break
A - D
Safety switch
S
Non-contact safety sensor
H
Start button
EN
GND
L1
X1
X2
Y1
Y2
13
23
33
43
K1
K2
X7
X8
GND
PE
14
24
34
44
AES 2565/2566
K3
K4
N
51
52
M
3

Advertisement

loading

This manual is also suitable for:

Aes 2356Aes 2555Aes 2366Aes 2556 aes 2365Aes 2565Aes 2566