ENGLISH
A / E LOGICS CONNECTIONS
ANTIPANICO
PANIC ALARM
ANTIPANIQUE
PANIKSCHUTZ
ANTIPÁNICO
STOP
24 Vdc
+
FX
NC
1 2 3 4 5 6 7 8 9 10
OPEN
5
+
4
FX
3
2
1
P LOGIC CONNECTIONS
ANTIPANICO
PANIC ALARM
ANTIPANIQUE
PANIKSCHUTZ
ANTIPÁNICO
STOP
24 Vdc
CLOSE
+
NC NO
1 2 3 4 5 6 7 8 9 10
OPEN
24 VAC
MAX 5 W
LAMPADA SPIA
WARNING LIGHT
LAMPE TÉMOIN
KONTROLLAMPE
TESTIGO
5.3. DESCRIPTION OF TERMINAL STRIP
OPEN
This means any activating device with normally open contact,
whose activation causes the beam to perform an opening
movement. In automatic and semi-automatic logics, it
controls both opening and closing movements.
CLOSE
This means any activating device with normally open
contact, whose activation causes the beam to perform a
closing movement. (Present only in P logic).
STOP
This means all devices with normally closed contact, which
when activated stop movement of the barrier until a subse-
quent Open pulse is sent.
SAFETY
This means all devices (photocells, sensitive pneumatic
safety edges, magnetic coils) with normally closed
contact, which interrupt the movement of the beam
whenever there is an obstacle within their range.
PANIC
This means an activating device with normally closed
contact, which is activated in an emergency and causes
the beam to open, suspending its current status until the
RESET pushbutton is pressed.
5.4. PROGRAMMING THE MICROSWITCHES
Speed OP/CL
OP=0.8 CL=2.2 ON
OP=0.8 CL=0.8 OFF
1
2
3
4
5
6
Logic
SW1
SW2
A
ON
ON
With 5 sec. pre-flashing
E
OFF
ON
of warning lamp
P
ON
OFF
R(*)
OFF
OFF
LAMPADA SPIA
WARNING LIGHT
LAMPE TÉMOIN
KONTROLLAMPE
TESTIGO
NO
111213 14 15 16 17
FAAC
LAMP
M
VENTOLA
24 VAC
MOTOR
FAN
MAX 5 W
VENTILATEUR
LÜFTER
VENTILADOR
2
+
1
111213 14 15 16 17
FAAC
LAMP
M
230 VAC +6% -10%
VENTOLA
FAN
MOTOR
VENTILATEUR
LÜFTER
VENTILADOR
SW6
Pause Time
SW3 SW4 SW5
(sec)
Ø
OFF OFF OFF
5
ON
10
OFF
{
20
ON
10
OFF OFF
20
ON
30
OFF
40
ON
NOTE: To obtain a duty cycle of 100%, dip switch no. 6 must be
positioned as shown in Table 5.
Table 5
N L
NOTE: WHENEVER YOU CHANGE THE MICROSWITCH
230 VAC +6% -10%
PROGRAMMING, PRESS THE RESET PUSHBUTTON AFTERWARDS.
50 Hz
(*) IMPORTANT!: The R logic (remote) must be selected
only if there are two opposing barriers working
simultaneously. (See paragraph "624 SLAVE CARD", below.)
Fig. 16
OPERATION OF SAFETY DEVICES
In the A or E logics, it is possible to obtain two different
types of safety device operation, depending on the pause
times that are selected:
- PAUSE TIMES WITH LAMP PRE-FLASHING (10-20-30-40 sec):
the closing movement is stopped, then reversed on
N L
disengagement.
- PAUSE TIMES WITHOUT LAMP PRE-FLASHING:(0-5-10-20 sec):
the closing movement is reversed at once.
50 Hz
ALARM CONDITION
Fig. 17
It occurs in the following cases:
1) Enabling of panic input.
2) Activation of safety TIME-OUT device, which interrupts
the operation of the system when operating time
exceeds 30 sec.
3) Simultaneous triggering of the two limit switches.
4) Microprocessor reading anomaly (syncro).
The alarm condition is indicated by the quick flashing
(0.25 sec) of the warning light (if connected).
In this condition, all the functions of the system are
disabled. Normal operation is restored only after the
cause of the alarm has been eliminated and the RESET
pushbutton has been pressed.
OPERATION WITH THE DIFFERENT CONTROL LOGICS
Table 6 A Logic (AUTOMATIC)
impulse
beam
status
closed
open in pause
closing
opening
stopped
Table 7 E Logic (SEMI-AUTOMATIC)
impulse
beam
status
closed
OFF OFF
open
ON
OFF
closing
ON
OFF
ON
opening
OFF
ON
stopped
ON
ON
ON
ON
(*) If pre-flashing has been selected, the barrier closes after 5 sec.
16
BARRIER MODEL
620 SR 0.8 - 2.2
620 SR 0.8 - 0.8
OPEN
STOP
opens, recloses after
no effect
pause time
recloses at once (*)
stops counting
reverses movement
stops
no effect
stops
recloses at once (*)
no effect
OPEN
STOP
opens
no effect
recloses (*)
stops
reverses movement
stops
stops
stops
recloses (*)
no effect
ENGLISH
SW6
ON
OFF
SAFETY
PANIC
no effect
Beam opens and/
freezes pause time up
or remains open.
to disengagement
Alarm condition is
activated
(see relevant
see relevant
paragraph)
paragraph
no effect
no effect
SAFETY
PANIC
Beam opens and/
no effect
or remains open.
no effect
Alarm condition is
see relevant
activated
paragraph
(see relevant
no effect
paragraph)
no effect