Download Print this page

FAAC 620 SR Manual page 2

Hide thumbs Also See for 620 SR:

Advertisement

Table 4
LED
FCC
FCA
OPEN
CLOSED/FSW
STOP
ALARM
(*) P logic operation
(**) A / E logic operation
625 MPS CONTROL UNIT
J4
DECODER
J6
DS1
J3
DL6
DL5
DL1
DL2 DL3 DL4
DL6
DL5
DL1
TF1 TRANSFORMER
J1
REMOVABLE LOW-VOLTAGE TERMINAL
STRIP
J2
REMOVABLE POWER TERMINAL STRIP
J3
LIMIT SWITCH CONNECTOR
J4
DECODER CONNECTOR
J5
CONNECTOR FOR FSW, SLAVE, RELAY
BOARDS
J6
CONNECTOR FOR NTC PROBE
5.2. CONNECTING RADIO RECEIVERS
Use quick connector J4 to insert
one of the decoder or receiver
cards RP shown in boxes A - B - C.
Fit it with the components
oriented towards the centre of
the 625 MPS card.
625 MPS
Operation of Status LEDS
ON (contact closed)
closing limit switch not engaged
opening limit switch not engaged
activated
activated (*)/saf. disengaged (**)
deactivated
panic contact deactivated
R
625 MPS
P1
RESET
J5
J1
DL2 DL3 DL4
B
DECODER
SL - SLP DS
closing limit switch engaged
opening limit switch engaged
deactivated (*)/saf. engaged (**)
panic contact activated
F2
J2
J9
REMOVABLE MAINS POWER TERMINAL
STRIP
P1 RESET PUSHBUTTON
F1
F5A FUSE (MOTOR)
F2
T1.6A FUSE (ACCESSORIES)
DS1 PROGRAMMING MICROSWITCHES
DL1 OPEN IMPULSE LED (A/E/P LOG.)
DL2 CLOSE IMPULSE LED (P LOG.)
SAFETY CONTACT (A LOG.)
DL3 STOP IMPULSE LED
DL4 ALARM LED (PANIC)
DL5 OPENING LIMIT SWITCH LED
DL6 CLOSING LIMIT SWITCH LED
A
625 MPS
625 MPS
ENGLISH
OFF (contact open)
deactivated
activated
TF1
F1
J9
Fig. 15
PLUS
MINIDEC
SL/DS
C

Advertisement

loading

This manual is also suitable for:

625 mps