TROUBLESHOOTING
※ Load mode Check list
Display
Display contents
LED
R-1-ⓔ
Overload condition
R-1-ⓕ
Low temperature condition When ambient temperature is less than 72°F(22°C), LED blinks
R-1-ⓔ,ⓕ
(All LED not
Normal Condition
blink)
R-1-ⓖ
Exhibition Mode
F-1-ⓐ
COMP.
F-1-ⓑ
F-FAN High
F-1-ⓒ
F-FAN Low
F-1-ⓓ
F-DEF Heater
F-1-ⓔ
C-FAN High
F-1-ⓕ
C-FAN Low
F-1-ⓖ
Homebar(Door) Heater
R-10-ⓓ
Ice maker full
F-10-ⓔ
Dispenser Heater
F-10-ⓖ
Damper Open
F-1-ⓑ,ⓒ
F-FAN Highest
Operation contents
When ambient temperature is more than 93°F(34°C), LED blinks
When ambient temperature is between 73°F(23°C) and 91°F(33°C)
LED blinks at the display mode.
When COMP operates, applicable LED blinks.
When FZ compartment FAN operates with high speed, applicable
LED blinks.
When FZ compartment FAN operates with low speed, applicable
LED blinks.
When FZ compartment defrost heater operates, LED blinks
When compressor FAN operates with high speed, applicable LED
blinks.
When compressor FAN operates with low speed, applicable LED
blinks.
When Homebar(Door) heater operates, applicable LED blinks.
When the Ice Maker's Bucket is full, applicable LED blinks
When Dispenser heater operates, applicable LED blinks.
When damper open, applicable LED blinks.
When FZ compartment FAN operates with highest speed, applicable
LED blinks.
54