Troubleshooting; Light Indicators - Stoelting SO218B Operator's Manual

Table of Contents

Advertisement

4.1 LIGHT INDICATORS

The machine has two lights that alert the user if a problem occurs: an ADD MIX light and a Diagnostic Light.
The ADD MIX light fl ashes to alert the operator to a low mix condition. It does so by monitoring the mix level in the
hopper. When the ADD MIX light is fl ashing, refi ll hopper immediately.
The Diagnostic Light fl ashes if an error occurs. Refer to the chart below for details.
Indication
On
Conditions
Defrost Mode
Self
N/A
Correction
Every 7 minutes
Operation
the auger runs
for 90 seconds.
End Defrost
Mode by turning
Clean/Off/On
switch OFF then
Corrective
turning it back
Action
ON. Opening
the spigot also
ends Defrost
Mode.

4.2 TROUBLESHOOTING

PROBLEM
1 Power to machine is off.
2 Blown fuse or tripped circuit.
Machine does not
3 Freeze-up (auger will not turn).
run.
4 Front door not in place.
1 Drive belt failure.
Machine will not
2 Consistency temperature setting is too
shut off.
3 Refrigeration problem.
1 Consistency temperature setting is too
Product is too fi rm.
Operators Manual
#513679
SECTION 4
TROUBLESHOOTING
One Blink
Torque is not
met after 20
minutes
current with a 3 second pre-stir. If current
is sensed, the machine returns to normal
N/A
Timers or until
torque switch
remains closed
for 3 seconds.
Contact Service
Technician
POSSIBLE CAUSE
fi rm.
fi rm.
Two Blinks
Drive current is not sensed
The machine attempts to sense drive
operation. If current is not sensed, the
machine waits 7 minutes and tries to
sense current with another 3 second
pre-stir. After the third attempt, the
compressor runs on timers.
Timers
Contact Service Technician
1 Supply power to machine.
2 Replace or reset.
3 Turn Clean/Off/On switch Off for 15 minutes,
then restart.
4 Assemble front door in place.
1 Replace drive belt.
2 Turn Consistency Adjustment screw counter-
clockwise.
3 Check system. (Call distributor for service)
1 Turn Consistency Adjustment knob counter-
clockwise.
13
Three Blinks
Machine left in clean
mode for over 20
minutes
N/A
Off
Turn CLEAN-OFF-
ON switch to OFF
(middle) position then
turn the switch to ON.
REMEDY
SO218B Model Machine

Advertisement

Table of Contents
loading

Table of Contents