Advertisement

Model CBE
OPERATORS MANUAL
Manual No. 513850
Rev.2

Advertisement

Table of Contents
loading

Summary of Contents for Stoelting CBE117

  • Page 1 Model CBE OPERATORS MANUAL Manual No. 513850 Rev.2...
  • Page 3 DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood. If problems develop or questions arise in connection with installation, operation, or servicing of the machine, contact Stoelting. Clearbowl Service Information: 888.429.5920 (U.S.
  • Page 4: Safety Information

    CAUTION If you need to replace a part, use genuine Stoelting The signal word “CAUTION” indicates a potentially parts with the correct part number or an equivalent hazardous situation, which, if not avoided, may result part.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS Section Description Page Description and Specifi cations Description ....................1 Specifi cations ..................... 2 Installation Instructions Safety Precautions ..................3 Shipment and Transit .................. 3 Machine Installation ..................3 Initial Set-Up and Operation Operator’s Safety Precautions ..............5 Operating Controls and Indicators ..............
  • Page 7: Description And Specifi Cations

    CBE machines. This manual applies to all CBE model machines in single, double and triple tank confi gurations. Figure 1-1 Model CBE117-37 Figure 1-2 Model CBE127-37 Figure 1-3 Model CBE167-37 Owner’s Manual #513850 Rev.2...
  • Page 8: Specifi Cations

    SPECIFICATIONS Model CBE117 Model CBE127 Model CBE167 Dimensions Machine Machine Machine width 9-1/2’’ (24,1 cm) 16-1/8’’ (41,0 cm) 24-1/2’’ (62,2 cm) height 30-3/4’’ (78,1 cm) 30-3/4’’ (78,1 cm) 30-3/4’’ (78,1 cm) depth 22’’ (55,9 cm) 22’’ (55,9 cm) 22’’ (55,9 cm)
  • Page 9: Installation Instructions

    Altering the plug to fi t into an outlet of different con- customer must place claim for damages and/or shortages fi guration may cause fi re, risk of electrical shock, in shipment with the carrier. Stoelting, Inc. cannot make product damage and will void warranty. any claims against the carrier.
  • Page 10 Owner’s Manual #513850 Rev.2 CBE Model Machines...
  • Page 11: Initial Set-Up And Operation

    SECTION 3 INITIAL SET-UP AND OPERATION 3.1 OPERATOR’S SAFETY PRECAUTIONS 3.2 OPERATING CONTROLS AND INDICATORS SAFE OPERATION IS NO ACCIDENT; observe these Before operating the machine, it is required that the op- rules: erator know the function of each operating control. Refer to Figure 3-1 for the location of the operating controls on Know the machine.
  • Page 12: Assembly Of Machine

    in the desired position, push the lever clockwise to lock it in place. Unlock the spigot by moving the lever counterclockwise. CAUTION Pinch Point When the spigot handle is locked in the open po- sition it can pinch and cause injury. Do not place Arrow your hand between the spigot handle and spigot Buttons...
  • Page 13: Sanitizing

    Press the gear onto the back of the horizontal Mix sanitizer according to manufacturer’s instructions to auger and install the auger. provide a 100 parts per million (ppm) strength solution and check the solution with chlorine test strips. Allow Place the gasket into the bottom groove on the sanitizer to contact the surfaces to be sanitized for 5 tank.
  • Page 14: Removing Mix From Machine

    Place the top cover onto the tank. Make sure the After the mix has been removed from the machine, follow metal contacts at the back of the cover are on the steps below to disassemble the parts. the outside of the tank. The contacts must make a circuit with the contact wires for the auger and CAUTION refrigeration system to operate.
  • Page 15: Routine Cleaning

    Prepare sanitizing solution according manufacturer’s instructions to provide a 100 ppm strength solution. Mix the sanitizer in quantities of no less than 2 gallons of 90° to 110°F (32° to 43°C) water. Check the strength of the sanitizing solution. Use a chlorine test strip and color chart to make sure the solution has 100 ppm.
  • Page 16 Owner’s Manual #513850 Rev.2 CBE Model Machines...
  • Page 17: Settings

    The Defrost Off setting determines when the 4.2 SETTINGS defrost mode stops and the machine returns to regular operation. Stoelting recommends a defrost LAMP mode for a minimum of 4 hours. The lamp can be set to On or Off using the arrow buttons.
  • Page 18 MAX TEMP The Max Temp setting will display a warning if the temperature of the product is greater than the setting. Press the Auger Movement button to enable or disable the warning and press the Menu button to save the setting and go to the next screen.
  • Page 19: Troubleshooting

    SECTION 5 TROUBLESHOOTING 5.1 CONTROL ALARMS REFILL The Refi ll alarm indicates that the product level When the display blinks, press the Menu button for a in the tank is below the probe and the autofi ll second. The display will show one of the following alarms: system is not refi...
  • Page 20 Owner’s Manual #513850 Rev.2 CBE Model Machines...
  • Page 21: Replacement Parts

    SECTION 6 REPLACEMENT PARTS 6.1 DECALS Part Description Quantity 324996 Decal - Pull 1 per tank 324997 Decal - Stoelting 1 per tank 6.2 TANK AND COVER 314229 493133 292380 431215 493131 724064 396769 Part Description Quantity 292380 Contact Assembly...
  • Page 22: Handle Assembly And Auger Parts

    6.3 HANDLE ASSEMBLY AND AUGER PARTS 538620 674222 221459 538621 674210 221457 624700 405580 405585 625549 221458 674211 396696 732394 314225 428096 442129 142081 175558 442128 Part Description Quantity 142081 Base - Tank Clamp 2 per tank 175558 Locking Screw - Tank Clamp 2 per tank 221457 Bushing - Transmission Shaft...
  • Page 23 CLEAR BOWL SERIES EQUIPMENT 1. Scope: PW Stoelting, L.L.C. (“Stoelting”) warrants to the first user (the “Buyer”) that the compressors of clear bowl series equipment supplied or manufactured by Stoelting will be free from defects in materials and workmanship under normal use and proper maintenance appearing within five (5) years, and that...