Battery Replacement

2 x AA Batteries
Alkaline or Nickel Metal Hydride (NiMh) ONLY!
Ensure batteries are installed as indicated inside the battery compartment.
The combined voltage of the batteries must be greater than 1.9 VDC for the CS-IPRO to power on.

Security

If the SECURITY jumper on the rear of CS-DMX control station is installed in the ENABLED
position, the security KEY set in the CS-IPRO must match the security KEY set in the CS-DMX
control station to make any changes to the DMX channel patch configuration. The SECURITY
jumper is installed in the DISABLED position by factory default. If security is required, it should be
implemented at the time of installation. Refer to SECURITY menu items EDIT KEY, SET KEY and
GET KEY on page 10 for further details.

User Interface

The user interface provides access to all of the configuration menu items. It consists of an LCD
display, four (4) programming switches and a power ON/OFF switch. Within a few minutes most
users will find the menu structure very intuitive and easy to navigate. All configuration settings are
automatically stored into an on-board internal EEPROM.
LCD Display
The LCD display is capable of displaying 2 lines of 8 characters. The LCD backlight automatically
turns on when there is activity and turns off after two (2) minutes of inactivity. The LCD contrast
can be easily adjusted for optimum viewing. Refer to menu item "LCD VIEW ADJUST" on page 8
for further details.
Programming Switches
The MENU UP/DOWN
switches are used for navigating through the various configuration
(
)
menu items. They also allow for programming of other specific parameters within a selected
menu. Pressing and holding either switch will speed up the scroll rate, which can be helpful to
speed up the configuration time.
The EXECUTE
switch is normally used to select/enter a menu item, advance forward
(
)
within a selected menu item, toggle between parameters within a selected menu item or select
parameters within a menu.
The ESCAPE (
) switch is normally used to back up within a selected menu item one step at a
time or exit the menu completely.
Power ON/OFF Switch
Press the ON/OFF switch to power on. Press and hold the ON/OFF switch to power off.
The CS-IPRO will automatically power off after 10 minutes of inactivity.
www.johnsonsystems.com