Typical Application Procedures - JOHNSON SYSTEMS CS-IPRO User Manual

Wireless hand-held programmer for cs-dmx series control stations
Table of Contents

Advertisement

15. FIRMWARE
View the firmware version running on the CS-IPRO microcontroller.
VER X.X
VER X.X
Indicates the firmware version running on the CS-IPRO microcontroller.
16. SERIAL #
View the CS-IPRO unique six-character silicone serial number.
XXXXXX
XXXXXX
Indicates the CS-IPRO unique six-character silicone serial number.
17. BATTERY
View the battery voltage level and status.
X.X OKAY
The batteries should be replaced when a low (LOW) battery voltage level is
detected. Once the batteries are at a critical (CRIT) voltage level, the CS-IPRO will
automatically save the DMX channel patch data and power down after 5 seconds.
3.0 OKAY
The bottom line indicates the battery voltage level (3.0) and status (OKAY).
2.2 LOW
Indicates a low (LOW) battery voltage level between 2.2 and 2.1 VDC.
2.2 CRIT
Indicates a critical (CRIT) battery voltage level of less than 2.1 VDC.
18. PRINTOUT
Print the DMX channel patch for a selected slider or all sliders.
PATCH
Prints out the DMX channel patch saved in the CS-IPRO memory only.
TThe CS-IPRO is capable of printing out the DMX channel patch for a selected slider
(01 to 12), or all (ALL) of the sliders at once.
Point the CS-IPRO infrared LED window directly at the hand-held printer (Johnson
System Inc., Part Number: JS-IP) infrared LED window, within 6' (1.8 m).
PRINTOUT
Press EXECUTE to enter the menu.
SS>01
Indicates the selected slider (SS) number (01) to printout.
SS>ALL
Press MENU (
PRINTING
Press EXECUTE to printout the DMX channel patch for the selected slider(s).
DONE !!!
Displayed briefly to indicate data has been sent to the hand-held printer.
Press ESCAPE to exit the menu.
19. LCD VIEW
Adjust the contrast of the LCD Display for optimum viewing.
ADJUST
LCD VIEW
Press EXECUTE to enter the menu.
ADJUST
Press MENU (
Press ESCAPE to exit the menu.

Typical Application Procedures

1.
Configure the DMX channel patch for a CS-DMX control station from scratch.
A) CLEAR PATCH
be sure the DMX channel patch data is cleared (blank) in the CS-IPRO.
B) EDIT PATCH
edit and configure the DMX channel patch for each slider as required.
C) CHECK PATCH
confirm the DMX channel patch is correct for each slider. EDIT PATCH again if
corrections are required.
D) SET CS PATCH load the DMX channel patch into the CS-DMX control station.
E) SAVE PATCH
save (backup) the DMX channel patch into the EEPROM memory module.
2.
Edit the DMX channel patch for a CS-DMX control station.
A) GET CS PATCH load the DMX channel patch from the CS-DMX control station into the CS-IPRO.
B) EDIT PATCH
edit and reconfigure the DMX channel patch for each slider as required.
C) CHECK PATCH
confirm the DMX channel patch is correct for each slider. EDIT PATCH again if
corrections are required.
D) SET CS PATCH load the edited DMX channel patch into the CS-DMX control station.
E) SAVE PATCH
save (backup) the DMX channel patch into the EEPROM memory module.
www.johnsonsystems.com
) to select the slider number from 01 to 12 or ALL to print.
) to adjust the LCD contrast.