- NI IMPORTANT NOTE: IMPORTANT NOTE: The circle fireplace is intended as a secondary source of The circle fireplace is intended as a secondary source of heating and not designed to be a primary heat source. heating and not designed to be a primary heat source.
Page 3
VisionLINE Circle - I VisionLINE Circle - I VisionLINE Circle - I 0147.8 0484 R242 R242 125.8 0100 VisionLINE Circle - NI VisionLINE Circle - NI 0147.8 VisionLINE Circle - NI 341.2 125.5 0100 Central - secondary - tertiary AIR CONTROL...
Page 4
The VisionLINE Circle-AU Using AU Default Flue kit (Solid 8” or Mesh) Circle – NI* Circle – I* Min. Clearance from firebox to rear wall 550mm 125mm Min. Clearance from firebox to side wall 575mm 550mm 300mm 300mm Min distance from firebox opening to floor protector front 107.5mm...
Page 5
Using AU Default flue kit Circle Circle I with solid or mesh 8” Min Clearance from firebox to 450mm 175mm corner walls Depth of floor protector 785mm 785mm Min Distance from firebox 300mm 300mm opening to floor protector front Min distance from firebox to 107.5mm...
Unit operation Unit operation Unit operation Unit operation First fire When lighting your fire for the first time, it can be expected that some smoke may emit from the outside of the fireplace as the paint cures. Please ensure you open doors and windows to allow for ventilation during this process. First fire First fire The door is sealed using a rope gasket which is inside the door frame.
Page 13
Resetting the unit for room air combustion (Circle-I) Your Circle-I unit is set from factory to use VisionLINE AIR flue which draws air for combustion from outside. If you are using a Australian Default flue kit, you will need to change the air intake so Your Circle-I unit is set from factory to use VisionLINE AIR flue which draws air for combustion the fire can draw air from the room.
Page 14
Removing the baffle for flue cleaning Removing the baffle for flue cleaning Removing the baffle for flue cleaning Step 1 Remove the two metal bolts shown in figure 1 Bolts Remove the two metal bolts shown in figure 1 Now remove the upper top plate as shown in Remove the two metal bolts shown in figure 1 Bolts Bolts...
Page 15
Flue Spigot Seating The VisionLINE Circle has a spigot which is designed to have the crimped end of a 6 inch (150mm) flue pipe located OVER the spigot and sit on the gutter provided on the casting. I Circle Unit with top plate removed...
Need help?