COLD WEATHER OR EXTENDED STORAGE
3. Place the O‑ring on the drain plug and apply Perfect Seal to the threads.
Install the drain plug in the module drain hole. Tighten the drain plug to
finger‑tight.
a
c
a -
Gen 3 Cool Fuel Module
b -
Drain plug
c -
O‑ring
Tube Ref
No.
19

Battery Storage

Whenever the battery will be stored for an extended period of time, be sure the
cells are full of water and the battery is fully charged and in good operating
condition. It should be clean and free of leaks. Follow the battery
manufacturer's instructions for storage.

Recommissioning the Power Package

1. Ensure that all cooling system hoses are connected properly and hose
clamps are tight.
Disconnecting or connecting the battery cables in the incorrect order can
cause injury from electrical shock or can damage the electrical system.
Always disconnect the negative (‑) battery cable first and connect it last.
eng
b
Description
Perfect Seal
Where Used
Drain plug threads
CAUTION
!
99
50410
Part No.
92-34227Q02

Hide quick links: