Download Print this page

Danfoss NovoCon S Operating Manual page 2

High accuracy

Advertisement

NovoCon® S - High Accuracy Actuator
®
NovoCon S
003Z8504
Actuator for AB-QM DN10-32
Control signal: BACnet MS/TP, Modbus RTU, 0-10V, 0-20mA
Power: 24VAC/DC, 50/60 HZ
Force: 90N. Stroke: 7 mm. Speed: 3-24s/mm
Consumption: 3.3VA running. Standby 0.9W
IP54/40, -10T55
Presettings
NovoCon® S
Safety Note
To avoid injury and damage to persons and devices, it is absolutely
necessary these instructions are carefully read and observed prior
to assembly and commissioning.
Necessary assembly, start-up, and maintenance work must be
performed only by qualified, trained and authorised personnel.
Switch off the power line before wiring the actuator.
Safety Note
Connect via safety isolating transformer.
Galvanic separations shall be provided for segments crossing buildings.
Part Name
部件名称
Pb/
Union nut /
连接螺母
O: Indicates that this hazardous substance contained in all of the homogeneous material for this part is below the limit requirement in GB/T 26572;
表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定的限量要求以下。
O:
X: Indicates that this hazardous substance contained in at least one of the homogeneous material for this part is above the limit requirementw in GB/T 26572;
表示该有害物质至少在该部件的某一均质材料中的含量超出
X:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | DHS-SRMT/SI | 2018.11
®
NovoCon S
003Z8504
E100 VXX
01
Actuator for AB-QM DN10-32
281624
Control signal: BACnet MS/TP, Modbus RTU, 0-10V, 0-20mA
0030471
Power: 24VAC/DC, 50/60 HZ
Force: 90N. Stroke: 7 mm. Speed: 3-24s/mm
Consumption: 3.3VA running. Standby 0.9W
III
IP54/40, -10T55
DIP Switch
1
2
3
DIP Switches 1 to 7 are used to assign the MAC address manually. Default MAC address assignment
method is Auto MAC addressing for BACnet MS/TP and DIP Switches for Modbus RTU.
For termination of last unit on the field bus, turn DIP Switch 8 ON.
Dip switch 9 is not used.
Dip switch 10 is used to select between BACnet MS/TP (OFF=Default) and Modbus RTU (ON).
When the protocol is changed on DIP Switch 10, a power cycle is required.
Application mode:
MSV:9 / 32810
Digital control (default), Analog
control, CO6 mode, Inverted
CO6 mode, CO6 without alarms,
Inverted CO6 without alarms
Hg/
X
O
GB/T 26572
E100 VXX
Serial number and QR code can be removed from the
281624
6430 Nordborg, Denmark
NovoCon® S label and added to installation drawing.
0030471
6430 Nordborg, Denmark
MADE IN SLOVENIA
01
E100 VXX
281624
III
0030471
4
5
6
7
8
9
10
ON
OFF
Select Valve Type
MSV:3 / 32802
(default AB-QM DN 15)
Safety Note
If the NovoCon® S network is supplied with two or more AC power
boosters, caution must be observed when disconnecting one of the
transformers from the high voltage power line. As the NovoCons are
connected in a daisy chain, there may be high voltage on the primary
side of the disconnected power supply. Disconnect always both the primary
and secondary side of the transformer.
Disposal instruction
This product should be dismantled and its components sorted if
possible, in various groups before recycling or disposal.
Always follow the local disposal regulations.
有害物质含量表
Hazardous Substances Table/
Cd/
六价铬
O
规定的限量要求。
MADE IN SLOVENIA
01
E100 VXX
281624
0030471
Device Object
Instance Number
Select application
MSV:10 / 33811
Heating (default)
Cooling
Cr(VI)/
PBB/
多溴联苯
O
O
eady agreed.
Design Flow Rate
AV:30 / 32796 Heating
AV:31 / 32798 Cooling
PBDE/
多溴二苯醚
O
73690900/VI.HU.M2.02

Advertisement

loading