1. Lever replacement
As per figure A,Remove the old lever along the
axis direction.
As per figure B, insert the new lever rib into the
corresponding control valve slot. The installation
is completed with a "click" sound.
A
3. Regulator replacement
Rotate the lever in the working position, clip out the
regulator from the inlet tube by pliers.
Press the new regulator into the bottom of the inlet
tube. The regulator replacement is completed.
Then rotate the lever back to non-working position.
Regulator
B
2.Nozzle replacement
As per figure A, Pull out the tube and do not release
then remove the old nozzle along the axis direction.
As per figure B, insert the new nozzle into the tube
along the corresponding slot. The nozzle
replacement is completed.
4. Water hose leaking solution
If water leaks from the two ends of water hose,
re-tighten the nuts to avoid water leaking.