IMPORTANT:
BEFORE STARTING THE EQUIPMENT,
READ THE CONTENTS OF THIS MANUAL, WHICH MUST
BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR
THE ENTIRE OPERATIVE LIFE-SPAN OF THE MACHINE.
THIS EQUIPMENT MUST BE USED SOLELY FOR WELD-
ING OPERATIONS.
1 SAFETY PRECAUTIONS
WELDING AND ARC CUTTING CAN BE HARMFUL TO
YOURSELF AND OTHERS. The user must therefore be edu-
cated against the hazards, summarized below, deriving from
welding operations. For more detailed information, order the
manual code 3.300.758
ELECTRIC SHOCK - May be fatal.
· Install and earth the welding machine according to
the applicable regulations.
· Do not touch live electrical parts or electrodes with
bare skin, gloves or wet clothing.
· Isolate yourselves from both the earth and the workpiece.
· Make sure your working position is safe.
FUMES AND GASES - May be hazardous to your health.
· Keep your head away from fumes.
· Work in the presence of adequate ventilation, and
use ventilators around the arc to prevent gases from
forming in the work area.
ARC RAYS - May injure the eyes and burn the skin.
· Protect your eyes with welding masks fitted with fil-
tered lenses, and protect your body with appropriate
safety garments.
· Protect others by installing adequate shields or curtains.
RISK OF FIRE AND BURNS
· Sparks (sprays) may cause fires and burn the skin;
you should therefore make sure there are no flam-
mable materials in the area, and wear appropriate
protective garments.
NOISE
This machine does not directly produce noise
exceeding 80dB. The plasma cutting/welding proce-
dure may produce noise levels beyond said limit;
users must therefore implement all precautions required by
law.
PACEMAKERS
· The magnetic fields created by high currents may
affect the operation of pacemakers. Wearers of vital
electronic equipment (pacemakers) should consult
their physician before beginning any arc welding, cutting,
gouging or spot welding operations.
EXPLOSIONS
· Do not weld in the vicinity of containers under pres-
sure, or in the presence of explosive dust, gases or
fumes. · All cylinders and pressure regulators used in
welding operations should be handled with care.
6
ELECTROMAGNETIC COMPATIBILITY
This machine is manufactured in compliance with the
instructions contained in the harmonized standard EN50199,
and must be used solely for professional purposes in an
industrial environment. There may be potential difficul-
ties in ensuring electromagnetic compatibility in non-
industrial environments.
IN CASE OF MALFUNCTIONS, REQUEST ASSISTANCE
FROM QUALIFIED PERSONNEL..
Do not dispose of electrical equipment
together with normal waste!In observance of
European Directive 2002/96/EC on Waste
Electrical and Electronic Equipment and its
implementation in accordance with national law, electri-
cal equipment that has reached the end of its life must
be collected separately and returned to an environmen-
tally compatible recycling facility. As the owner of the
equipment, you should get information on approved col-
lection systems from our local representative. By
applying this European Directive you will improve the
environment and human health!
2 GENERAL DESCRIPTIONS
2.1

SPECIFICATIONS

This machine was developed to handle the problems that
arise in auto body repair
NOTE: Only steel bodies.
It makes it possible to eliminate dents or bulges on the body,
working from just one side.
The welding machine must not be used for any other pur-
pose, such as defrosting pipes or performing mechanical
tasks. The machine was designed to be used by the opera-
tor using the planned control devices
2.2 EXPLANATION OF THE TECHNICAL SPECIFICA-
TIONS LISTED ON THE MACHINE PLATE
Serial number, which must be indicated on any
request regarding the welding machine
IEC 60974-1 The welding machine is manufactured according
EN 50199
to these international standards.
Single-phase
1 ~
device for charging and discharging the
capacitors
U0
Secondary open-circuit voltage
E
Welding energy
C
Capacity value
Uc
Voltage adjustable on the capacitors
U1
Rated supply voltage. The machine is set up for
voltages of 115V and 230V with automatic
voltage change.
1-50/60Hz 50- or 60-Hz single-phase power supply
I1 Max
Max. absorbed current at the corresponding
supply voltage.
IP23C
Protection rating for the housing. Grade 3 as the
second digit means that the equipment is
suit able for use outdoors in the rain.
C: The additional letter C means that the
equipment is protected against access to the
transformer-rectifier
with