Stand alone access control module
Table of Contents

Advertisement

Available languages

Available languages

MODULE DESCRIPTION
Installation terminal connector is located on the rear
Jumper JP4, that's placed on the left side of the terminal connector
allows to reset the installer PIN code to the factory default
(see page 37).
Use this function only in case to forget this code.
With the system switched on, change the jumper position
to reset the code and return it to the standby position.
MODULE PROGRAMMING
It will be necessary to enter into the programming menu to configure the system properties.
Two different programming menues are available: installer, that allows to modifiy any of the
system properties and user, that only allows to change the relay activation codes,
the user code and to disable the keypad acknowledgement signal.
Programming options with black text and white background are availables in both menues;
options with white text and black background are only availables on installer menu.
The module will automatically exit from the configuration menu after 2 minutes with no operation.
M
odule description
part of the module. The correspondance of each
terminal is as follows:
~, ~ :
power supply input.
B+ :
positif for battery.
B– :
negatif for battery.
C1 :
relay 1 common terminal.
N1 :
relay 1 output terminal.
NC2 :
relay 2 normally closed output.
C2 :
relay 2 common terminal.
NA2 :
relay 2 normally closed output.
P :
panic output.
Reset.
Standby.
P
rogramming methodes.
36
37
To enter into the programming menu, press key symbol and enter
To exit from the programming menu press key symbol at any moment.
On both cases, the module will reproduce 5 fast acoustic tones.
2
7
To program the access control functions, it will be necessary to enter the function field
followed by the corresponding value. Sometimes, this value will be predefined
(i.e. relay 1 contact type) and sometimes will be selected by the installer.
Once into programming mode, the programming sequence is as follows:
1
1
1
8
If a wrong value has been introduced, press cancel key (C). The keypad will reproduce 1 large
acoustic tone. If cancel key has been pressed during the introduction of the function field,
even after the confirming tones, the function field must be entered again; if cancel key
has been pressed during the introduction of the function value, introduce a new value.
3
C
MODULE PROGRAMMING
the installer PIN code (factory default: 271828)
or the user PIN code (factory default: 314159).
1
8
2
8
or
3
1
4
Enter the function field to be programmed: this is a
2 digits code. The module will reproduce a 2 slow
acoustic tones.
Enter the value of the function under programming.
2
8
Once the value has been entered, the module
will reproduce a 4 slow acoustic tones.
Enter the next function field to be programmed or
press key symbol to exit from the programming mode.
C
1
2
1
5
9
C
C
E
nter and exit from
programming.
1
5
9
P
rogramming structure
and sequence.
9
4
C

Hide quick links: