golmar Stadio Plus T3301ML Instruction Manual page 19

Stand alone access control module
Table of Contents

Advertisement

Available languages

Available languages

MODULE INSTALLATION
E
mbedding box positioning.
1650
The upper part of the module should be placed at 1,65m. height roughly.
The hole dimensions are: 125(W) x 140(Al) x 57(D) mm.
The module has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers.
Break the bottom flange
to pass the cables through.
34
1850
1450
P
reparing the embedding box.
Pass the wiring through the hole made in
the bottom part of the embedding box.
Level and flush the embedding box.
Once the embedding box is placed,
remove the protective labels
from the attaching door panel holes.
35
H
old the module on the embedding box.
Select a direction to open the module; this selection should ease
the door panel wiring.
The opening direction will be settled through the hinges position,
that must be passed through the header clips as shown.
For example, if the hinges are placed on both clips of the lower
header, the module will open downwards; if they are placed
on the right clips of both headers, the module will open to left.
To hold the module on the embedding box,
insert the hinges in the embedding box lockers
as shown.
Fix the module by using the supplied screws.
Finish the module assembly by pressing the closing heads.
POWER SUPPLY INSTALLATION
I
nstalling the TF-104 transformer.
3,5 x 25
DIN-7971
To install the transformer directly on the wall,
insert the fixing flanges.
Drill two holes of Ø6 mm. and
insert the wallplugs.
3,5 x 25
DIN-7971
Fix the transformer with the specified
screws.
The transformer can be installed on a DIN guide (3 units) simply pressing it.
To disassemble the transformer from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
MODULE INSTALLATION
The transformer must be installed in a dry and
protected place. It's recommended to protect
the transformer by using a thermo-magnetic
circuit breaker.
DIN 46277