LOCK RELEASE INSTALLATION
L
ock release installation.
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole . In case of wood door,
use a Ø3mm. drill .
IMPORTANT: a varistor is supplied with the access control module.
In case to connect an a.c. lock release in one of the relay outputs
and in order to ensure a proper system operation, place the varistor
on the lock release terminals directly.
SCHEMATIC DIAGRAMS
The wiring of the access control module on 'Stadio Plus' door panels will depends
on the installation type. Use the power supply connected to the door panel.
Audio and video systems with digital installation.
3301/AL
EL500 or EL501 microprocessed modules
Access control module
1
2
3
C
4
5
6 0
7
8
9
CN1
~ ~
B+ B- C1 N1
NC2
C2
NA2
P
CV-
CV+
3,5 x 25
DIN-7972
M 4 x 8
DIN-963
C
ombined on 'Stadio Plus'
door panels.
FA-Plus/C or FA-Plus
or coded panels
power supplies
CN1
SEC
PRI
-
+ -
~
+
D A
A
V
V
V
V
out
in
in-
in+
Malla
out+
out-
Mains
42
43
One access door audio systems with 4+'n' installation.
Access control module
~ ~
Several access doors systems with 4+'n' installation.
Access control module
~ ~
B+ B- C1
(*) The 4+'n' systems use 12Va.c. lock releases: the supplied varistor must be connected
~
to the lock release.
SCHEMATIC DIAGRAMS
3301/AL
EL550, EL554 or EL555
sound modules
1
2
3
C
4
5
6 0
7
8
9
CN1
CN1
-
B+ B- C1
N1
NC2
C2
NA2
P
L1 L2
CP
P
CV
3301/AL
EL551 sound module
1
2
3
C
5
4
6 0
7
8
9
CN1
CN1
N1
NC2
C2
NA2
P
L1 L2
CP
P
-
CO INH
C
ombined on 'Stadio Plus'
door panels.
TF-104
transformer
SEC
PRI
~
~
~
~
~2
~1
Mains
(*)
TF-104
transformer
SEC
PRI
~
~
~
~
CV
CV
~2
~1
Mains
(*)