ENGLISH
Connection cable
• The appliance is supplied with the
connection cable.
• Replace the damaged mains cable only
with the spare parts cable. Contact your
IKEA store call centre.
Caution! Do not solder any
wires!
One-phase connection
The mains cable is provided for a one-
phase connection.
Two-phase connection for maximum
power (7200 W)
One-phase connection - 230 V~
N
L
Power limitation
Originally the appliance works at the
highest possible power level (7200 W).
To decrease or increase the power level:
1. Deactivate the appliance.
2. Touch
for 3 seconds. The display
comes on and goes off.
3. Touch
for 3 seconds.
on.
4. Touch
. P 72 comes on.
5. Touch
or
power level.
Power levels
• P 72 — 7200 W
• P 15 — 1500 W
• P 20 — 2000 W
• P 25 — 2500 W
• P 30 — 3000 W
Green - yellow
Blue and blue
Black and brown
or
comes
of the Timer to set the
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on each cable end (a special tool
required).
230V~
N
L
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and blue
Black
Brown
• P 35 — 3500 W
• P 40 — 4000 W
• P 45 — 4500 W
• P 50 — 5000 W
• P 60 — 6000 W
To confirm your selection wait until the
appliance deactivates automatically.
If you accidentally press
twice, a list of codes comes on.
This is only relevant for service
purposes. To leave this menu
touch
again or wait until the
hob deactivates automatically.
Caution! Make sure that the
selected power fits to the house
installation fuses.
38
400V 2~N
N
L1
L2
N
L1
L2

Hide quick links: