Riello Residence IN Condens KIS i User Instructions page 25

Table of Contents

Advertisement

Available languages

Available languages

CODE
DESCRIPTION
Signal of primary heat
AL91
exchanger cleaning (call
customer service)
Resetting the faults
Wait about 10 seconds before resetting nor-
mal operation conditions.
Then proceed as follows:
1
Display of the blinking alarm code
If just the blinking alarm is displayed it means
that a temporary stop was diagnosed, if the
fault is reset the boiler proceeds with regular
autonomous operation.
If, however, the boiler does not begin reg-
ular operations, a definitive lockout can be
brought about. In this case, proceed as de-
scribed in point 2.
2
Red led comes on and blinking alarm
code is displayed
Turn the mode selector (5) to
tion it on the desired position.
If the boiler performs the firing procedure
and resumes normal operation, the stop-
page can be attributed to a chance situation.
If the shut-down reoccurs however, you
should contact the r Technical Assistance
Service.
For AL41 faults
Check the pressure on the hydrometer under
the boiler; if it is less than 0.5 bar proceed as
follows:
− position the mode selector (5) to
1
2
6
STATUS
SIGNAL
and reposi-
3
5
4
− fill slowly by opening the filler tap
on the outside of the boiler until the
hand of the hydrometer is between 1
and 1.5 bar
filling
tap
− reposition the mode selector (5) on
the required position (summer or
winter).
If pressure drop is frequent, contact the r
Technical Assistance Service.
For fault AL60
The boiler is working normally, but does not
provide any stability of the domestic hot wa-
ter temperature that, in any event, is sup-
plied at a temperature of around 50°C.
The intervention of the r Technical Assis-
tance Service is required.
25