CLEANING INSTRUCTIONS
Cleaning Thermal FreshTrac
WARNING: DO NOT immerse the thermal server or its lid assembly in water or any other liquid. Do not place the
thermal server or lid in a dishwasher. Placing a thermal server in a dishwasher will void the warranty. Do not use
harsh powders or cleansers containing chlorine. Do not use a wire brush or pot scour to clean inside liner.
To avoid damage, DO NOT use a brush to clean the faucet or the inside of the faucet shank (outlet).
NOTE: The stem on the bottom of the lid has a built-in sensor used for the FreshTrac feature. Keep this
stem free from coffee oil build-up for proper operation.
Cleaning the Container
Prepare a mild solution of detergent and warm water.
Remove the server from the brewer and remove the lid.
Rinse.
2
Wash - Wipe the exterior surfaces of
the container with a sponge soaked
with the detergent solution to remove
spills and debris. Remove the lid and
Take a sponge brush and scrub out the
stainless steel liner and the lid.
3
Rinse - Rinse with clean, warm water.
Sanitize - Sanitize the interior of the server and the lid,
using a commercial sanitizer suitable for food grade
applications. Sanitize according to the directions on the
package.
5
Disassemble the faucet - Unscrew the handle/bonnet
assembly from the top of the faucet and remove it.
Inspect the seat cup for wear. Replace the seat cup if it is damaged.
6
Air Dry - Turn the container and lid upside down and allow to air dry.
Cleaning the Faucet Parts
7
Wash - Wash all faucet and gauge glass parts with the detergent
Clean the inside of the gauge glass with a gauge brush soaked with
detergent solution.
8
Rinse - Thoroughly rinse all parts with clean, warm water.
Sanitize - After rinsing, place all faucet and gauge parts in a sink to be sanitized. Immerse them in a
commercial sanitizer suitable for food grade applications. Sanitize according to the directions on the package.
Air Dry - Allow all parts to thoroughly air dry.
Reassemble - When dry, reassemble the handle/bonnet. Hand tighten the handle/bonnet onto the top of the
faucet assembly, reinstall the site gauge and cover. If replacing a broken gauge glass, carefully remove any
traces of glass from the silicone parts before inserting the new gauge glass tube. Reinstall the lid.
®
Dispensers (Daily)
Lid
Stem
Handle
Bonnet
Seat cup
Faucet
Assembly
WASH
RINSE
CI33
SANITIZE
Need help?
Do you have a question about the FreshTrac TFT Series and is the answer not in the manual?