Download Print this page

LEGRAND Mosaic 0 770 30 Assemnly Instructions page 3

6 a pushbuttons

Advertisement

Mosaic
TM
6 A pushbuttons
5. CONNECTION
(cont'd)
5.1 Wiring
Catalogue numbers: 0 770 32/42 - 0 792 32/42
Indicator function: Only possible with support frame Cat. No. 0 802 62.
Illuminated function: Illuminates the pushbutton in the dark.
1 - Unclip the rocker
2 - Insert indicator light Cat. No. 0 676 66
or indicator light Cat. No. 0 676 67
L
Catalogue number: 0 770 44
Indicator or illuminated function, use indicator light Cat. No. 0 676 69
(potential-free terminals).
Indicator light, 12 - 24 V, Cat. No. 0 667 61 DC : 0.2 mA ; AC : 0.4 mA
Indicator light, 24 - 48 V, Cat. No. 0 667 62 DC : 0.9 mA ; AC : 1.2 mA
Indicator light, 230 V, Cat. No. 0 667 69 AC : 0.15 to 3 mA.
Position
Indicator
676 69
AAWSS
230V
Connection via 2 automatic
terminals without release keys
6. OPERATION
Switch mechanism (handling force 2.6 to 3.5 N)
(Cat. Nos. 0 770 30/31/32/40/41/42/43)
Pull-cord mechanism (handling force 3 to 5 N) (Cat. No. 0 770 44)
Technical data sheet: F00421EN/02
CONTENTS
Position
Illuminated
3mA
0.15mA
Cat. No(s).: 0 770 30/31/32/40/41/42/43/44
0 792 30/32/40/42
7. TECHNICAL CHARACTERISTICS
7.1 Mechanical characteristics
Impact tests: IK04
Protection against liquids: IP41 (C15100)
7.2 Material characteristics
Rocker: ABS (RAL 9003)
Base: Polycarbonate
Rocker support: Polycarbonate
7.3 Electrical characteristics
Self-extinguishing: 650° C / 30 s
Voltage: 250 V
Current: 6A
7.4 Climatic characteristics
Storage temperatures: - 10° C to + 70° C
Operating temperatures: - 5° C to + 50° C
8. CLEANING
Surface cleaning with a cloth.
Do not use: acetone, tar remover, trichloroethylene.
N
8.1 Resistance to cleaning agents
Resistance to the following agents: Hexane (EN 60669-1), Methylated
spirits, Soapy water, Diluted ammonia, Diluted pure bleach 10%, Glass
cleaning substance, Pre-impregnated wipes.
8.2 Resistance to hospital-type cleaning agents.
Resistance to the following agents: Anios, Surfanos, Bactillysine, Diluted
hydrogen peroxide (35%).
Caution: A preliminary test should be carried out if other specific
cleaning products are to be used.
9. ACCESSORIES
Lights for pushbuttons with indicator light
Pushbuttons
0 770 32
0 770 42
0 792 32
0 792 42
0 770 44
Cord for pushbutton with pull-cord
Pushbutton
0 770 44
10. CONFORMITY - APPROVALS
Approvals in process: NF - CEBEC - EZU - BBJ - VDE - OVE - AENOR -
KEMA - MEEI - GOST - TSE.
Updated: 25/10/2011
Illuminated
0 676 66 (230 V)
0 676 67 (12-24-48 V)
0 676 69 (230 V / 0.15 mA)
0 676 69 (230 V / 0.3 mA)
0 676 61 (12-24 V)
0 676 62 (24-48 V)
Cord 1.5 m
Created: 04/12/2006
Indicator
0 898 05
3/3

Advertisement

loading

This manual is also suitable for:

Mosaic 0 770 31Mosaic 0 792 30Mosaic 0 770 43Mosaic 0 770 44