Summary of Contents for Avaya Ethernet Routing Switch 8300 Series
Page 1
Planning and Engineering — Power Considerations Avaya Ethernet Routing Switch 8300 NN46200-511, 05.03 May 2011...
Page 2
Avaya or the applicable third party. Avaya does not guarantee that these links will work all the time and has no control over the availability of the linked pages.
Contents Chapter 1: Regulatory Information and Safety Precautions........... International Regulatory Statements of Conformity.................. 5 National Electromagnetic Compliance (EMC) Statements of Compliance..........5 FCC Statement (USA only)........................5 ICES Statement (Canada only)......................... 6 Canadian Department of Communications Radio Interference Regulations..........6 Règlement sur le brouillage radioélectrique du ministère des Communications........
Page 4
Getting product training..........................37 Getting help from a distributor or reseller....................37 Getting technical support from the Avaya Web site.................. 38 Chapter 7: Translation of safety messages..............Harmful interference caution statement....................39 Mixed power supplies caution statement....................40 Index............................. Planning and Engineering — Power Considerations...
Read the information in this section to learn about regulatory conformities and compliances. International Regulatory Statements of Conformity This is to certify that the Avaya 8000 Series chassis and components installed within the chassis were evaluated to the international regulatory standards for electromagnetic...
CE Marking Statement (Europe only) EN 55 022 Statements This is to certify that the Avaya 8300 Series chassis and components installed within the chassis are shielded against the generation of radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
EN 55 024 Statement EN 55 024 Statement This is to certify that the Avaya 8300 Series chassis is shielded against the susceptibility to radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55 024 (CISPR 24).
CE Marking Statement (Europe only) EN 60 950 Statement This is to certify that the Avaya 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive.
Norma Oficial Méxicana (NOM): Exporter: Avaya Inc. 4655 Great America Parkway Santa Clara CA 95054 USA Importer: Avaya Communication de México, S.A. de C.V. Av. Presidente Masarik 111 Piso 6 Col. Chapultepec Morales Deleg. Miguel Hidalgo México D.F. 11570...
Norma Oficial Mexicana (NOM): Exportador: Avaya Inc. 4655 Great America Parkway Santa Clara, CA 95054 USA Importador: Avaya Communication de México, S.A. de C.V. Av. Presidente Masarik 111 Piso 6 Col. Chapultepec Morales Deleg. Miguel Hidalgo México D.F. 11570...
Denan Statement (Japan/Nippon only) Safety Messages This section describes the different precautionary notices used in this document. This section also contains precautionary notices that you must read for safe operation of the Avaya Ethernet Routing Switch 8300. Notices Notice paragraphs alert you about issues that require your attention. The following sections describe the types of notices.
Electrostatic alert: PRECAUCIÓN ESD (Descarga electrostática) El aviso de ESD brinda información acerca de cómo evitar una descarga de electricidad estática y el daño posterior a los productos Avaya. Electrostatic alert: CUIDADO ESD Os avisos do ESD oferecem informações sobre como evitar descarga de eletricidade estática e os conseqüentes danos aos produtos da Avaya.
Schäden an Avaya-Produkten verhindert. Caution: PRECAUCIÓN Los avisos de Precaución brindan información acerca de cómo evitar posibles interrupciones del servicio o el daño a los productos Avaya. Caution: CUIDADO Os avisos de cuidado oferecem informações sobre como evitar possíveis interrupções do serviço ou danos aos produtos da Avaya.
Avaya products. Warning: AVERTISSEMENT La mention Avertissement fournit des informations sur les moyens de prévenir les risques de blessure lors de la manipulation de produits Avaya. Warning: WARNUNG Warnhinweise bieten Informationen dazu, wie man Personenschäden bei der Arbeit mit Avaya-Produkten verhindert.
Danger High Voltage Notice Danger High Voltage Notice Voltage: Danger—High Voltage notices provide information about how to avoid a situation or condition that can cause serious personal injury or death from high voltage or electric shock. Voltage: La mention Danger—Tension élevée fournit des informations sur les moyens de prévenir une situation ou une condition qui pourrait entraîner un risque de blessure grave ou mortelle à...
Regulatory Information and Safety Precautions Danger Notice Danger: Danger notices provide information about how to avoid a situation or condition that can cause serious personal injury or death. Danger: La mention Danger fournit des informations sur les moyens de prévenir une situation ou une condition qui pourrait entraîner un risque de blessure grave ou mortelle.
Chapter 2: New in this release The following section details what's new in Avaya Ethernet Routing Switch 8300 Planning and Engineering — Power Considerations, NN46200-511 for Release 4.1: • Features on page 17 • Other changes on page 17 Features There are no new features affecting this document for this release.
Page 18
New in this release Planning and Engineering — Power Considerations May 2011...
Chapter 3: Introduction This guide provides information about the power considerations used in the Ethernet Routing Switch 8300 Series. Navigation • Power considerations on page 21 • Power cord specifications on page 33 Planning and Engineering — Power Considerations May 2011...
Page 20
Introduction Planning and Engineering — Power Considerations May 2011...
Chapter 4: Power considerations This chapter describes power considerations and specifications for the Ethernet Routing Switch 8300. Use this information for proper network design. Navigation • Ethernet Routing Switch 8301AC and 8302AC power supply on page 21 • Ethernet Routing Switch 8005DI DC power supply on page 22 •...
Power considerations Figure 1: Ethernet Routing Switch 8301AC power supply Figure 2: Ethernet Routing Switch 8302AC power supply Ethernet Routing Switch 8005DI DC power supply Each 8005DI DC power supply provides 1462 W of power to the switch. The following figure shows the 8005DI DC power supply you use in the 8306 and 8310 chassis.
Ethernet Routing Switch 8005 DC power supply Figure 3: 8005DI DC power supply Ethernet Routing Switch 8005 DC power supply Each 8005DC power supply provides 1462 W of power to the switch. The following figure shows the 8005DC power supply used in the 8306 and 8310 chassis. Planning and Engineering —...
Avaya recommends that you install each power supply on its own dedicated branch circuit. When you plug the power cord for each power supply into a separate AC circuit, the redundant power supply also provides protection against the disconnection or failure of an individual branch circuit or power supply failure.
Page 25
Determining the number of AC power supplies Table 2: Available system power for Ethernet Routing Switch 8306 and 8310 chassis Power Power Number Redundancy Module Fans Supply supply of power rating supplies 8301AC 100-120VA 600 W 450 W 90 W Yes 1+1 600 W 450 W 90 W...
2 An Ethernet Routing Switch PWR module at the default PoE power allocation of 200 watts supports an average of 4 watts over all 48 10/100/1000 802.3af ports. For technical specifications for Ethernet Routing Switch 8300 modules, see Avaya Ethernet Routing Switch 8300 Installation — Modules, NN46200-305. For PoE concepts and configuration, see Avaya Ethernet Routing Switch 8300 Configuration —...
AC power supply specifications your configuration. For the 8005DI DC power supply specifications, see 8005DI DC power supply specifications on page 29. 3. Consider your redundant power supply needs. If one power supply satisfies your system power consumption needs, a second power supply provides redundancy. If two power supplies satisfy your system power consumption needs, a third power supply provides redundancy.
Page 28
Power considerations Input current (nominal) 16 A 12 A Frequency range (nominal) 50-60 Hz 50-60 Hz Input VA 1600 VA 2234 VA Input power consumption 1584 W 2212 W Heat dissipation (thermal/output) 1515 BTU/hr 1508 BTU/hr Hold-up time 20 ms 20 ms DC output power ratings Maximum output power (combined) 1140 W (1050 W + 90 W...
8005DI DC power supply specifications Frequency range (nominal) 50-60 Hz 50-60 Hz Input VA 1192 VA 1768 VA Input power consumption 1180 W 1750 W Heat dissipation (thermal/output) 1126 Btu/hr 1195 Btu/hr Hold-up time 20 ms 20 ms DC output power ratings Maximum.
Power considerations DC output power specifications The following table describes the technical specifications for DC input power for Model 8005DI DC power supply. Table 7: DC output power specifications for Model 8005DI DC power supply Parameter Specifications Output power (maximum) 1462 W continuous, 1660 W peak with forced air cooling Modules...
Page 31
8005 DC power supply specifications DC output power specifications The following table describes the specifications for DC input power for Model 8005DC power supply. Table 9: DC output power specifications for Model 8005DC power supply Parameter Specifications Output power (maximum) 1462 W (1372 W + 90 W fans) Modules 3.3 V @ 150 A...
Page 32
Power considerations Planning and Engineering — Power Considerations May 2011...
International power cord specifications for the 8301AC power supply The following table lists specifications for international power cords for the 8301AC power supply. Table 10: International power cord specifications for the 8301AC power supply Avaya order number Country Plug and Specifications Typical plug Receptacle description...
Page 34
Power cord specifications Avaya order number Country Plug and Specifications Typical plug Receptacle description AA0020050 North America and Taiwan 250 VAC/15 A conductor size: NEMA6-15 male plug 14 AWG length: 2.5 M AA0020060 North America 250 VAC/15 A conductor size:...
Page 35
International power cord specifications for the 8301AC power supply Avaya order number Country Plug and Specifications Typical plug Receptacle description AA0020057 Australia 250 VAC/15 A conductor size: AS/NZ5 3112 male plug 1.5 mm length: 2.5 M AA0020058 United Kingdom and Ireland...
Page 36
Power cord specifications Planning and Engineering — Power Considerations May 2011...
Chapter 6: Customer Service Visit the Avaya Web site to access the complete range of services and support that Avaya provides. Go www.avaya.com or go to one of the pages listed in the following sections. Navigation • Getting technical documentation on page 37 •...
Customer Service Getting technical support from the Avaya Web site The easiest and most effective way to get technical support for Avaya products is from the Avaya Technical Support Web site at www.avaya.com/support. Planning and Engineering — Power Considerations May 2011...
Chapter 7: Translation of safety messages Harmful interference caution statement Caution: This device is a Class A product. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users are required to take appropriate measures necessary to correct the interference at their own expense.
Translation of safety messages Caution: ATTENZIONE Questo dispositivo è un prodotto di Classe A. Il funzionamento di questo apparecchio in aree residenziali potrebbe causare interferenze dannose, nel cui caso agli utenti verrà richiesto di adottare tutte le misure necessarie per porre rimedio alle interferenze a proprie spese.
Page 41
Mixed power supplies caution statement Não misture os tipos de fontes de alimentação no chassi do 8306 ou do 8310. Todos os módulos PoE 8348TX-PWR e 8348GTX-PWR instalados perdem energia PoE quando o chassi detecta diferentes fontes de alimentação. Caution: ATTENZIONE Non combinare tipi di alimentatori diversi nello chassis 8306 o 8310.
Page 42
Translation of safety messages Planning and Engineering — Power Considerations May 2011...
Index customer service ............statements of compliance ......... statements of conformity ..........distributor ..............documentation ............training ................ reseller ................ Planning and Engineering — Power Considerations May 2011...
Need help?
Do you have a question about the Ethernet Routing Switch 8300 Series and is the answer not in the manual?
Questions and answers