Summary of Contents for Taiji TSK-110A

  • Page 1: Operating Instructions

    Operating Instructions Sake Warmer TSK-110A TSK-210A TSK-220A TSK-420A TSK-130A TSK-230A TSK-110A TSK-130A...
  • Page 2: Table Of Contents

    Contents Introduction ............ 1 After Use ............12 Use ..............1 After-Sales Service ........14 Names of Parts ..........2 Specifications ..........15 Inspection and Preparation Before Use ..4 Instructions for Use ........7 Caution: Before attempting to connect or operate this product, please read the label on the bottom.
  • Page 3: Introduction

    Introduction • To use your new purchase correctly and safely, you are advised to carefully read this manual and fully understand it before use. • Keep the manual at hand for quick reference after reading it. • Be sure to receive your warranty of the product. •...
  • Page 4: Names Of Parts

    Names of Parts <TSK-110A, 210A, 220A, 420A> Bottle holder funnel Bottle holder (filter inside) Dispensing lamp Air suction port Water feeding port Water supply lamp Power lamp Manual switch Sake drain switch Power switch Water level meter Temperature indicator lamp...
  • Page 5 <TSK-130A, 230A> Joint hose Sake meter Sake meter fittings Water supply lamp Sake meter mounting screw Power lamp Sake meter mounting metal (* for TSK-130A only) Power switch Air relief hole Water feeding port Dispensing lamp Manual switch Temperature indicator lamp Temperature setting switch...
  • Page 6: Inspection And Preparation Before Use

    Inspection and Preparations Before Use 1. Check the instruction manual, and the accessories. 2. Choose a place for the sake warmer. • A level, stable place. • A well-ventilated place. • A place away from heat sources, such as a gas burner and cooking range, and free from exposure to direct sunlight.
  • Page 7 If you have a model TSK-110A, 210A, 220A, or 420A, go to step 5. If you have a model TSK-130A, or 230A, go to steps 6 and 7. 5. Clean the sake warmer heat exchanger pipe. (Fig. 3) This product is already cleaned inside before shipment.
  • Page 8 right or left of the main body. 2) Fit the sake meter in the sake meter fittings. 3) Remove the cap that is attached to the sake meter connection port. 4) Insert the joint part of the sake meter into the hole located on the side surface of the main body, and screw it in the sake meter connection port.
  • Page 9: Instructions For Use

    Instructions for Use Push the power cord plug into a wall outlet. Press the power switch. When the “power switch” is pressed, the “power lamp” is lit and the electric power begins to be fed. At the same time, the “water supply lamp” is lit and an alarm keeps sounding to indicate the “need for water supply.”...
  • Page 10 TSK-210A, and in about 35 minutes for the TSK-220A, TSK-230A, and TSK-420A.) If you have a model TSK-110A, 210A, 220A or 420A, go to steps 5 to 8. If you have a model TSK-130A, 230A, go to steps 9 to 12.
  • Page 11 • The relationship of the bottle holding position and the nozzle (sake outlet) between the TSK-220A and TSK-420A is classified into the right and left as illustrated below. Bottle holder (Right) Bottle holder (Right) Front Front Right nozzle (sake outlet) Right nozzle (sake outlet) TSK-220A TSK-420A...
  • Page 12 If you have a model TSK-130A, or 230A, go to steps 9 to Set the Cubitaner®. 1) Remove the cap from the mouth of the Cubitaner and confirm that the knob of the accessory valve A is set at “SHUT.” Then screw it in. Sake will leak out if this screw-in process is awkwardly followed.
  • Page 13 If this cap is removed, connect the sake meter or screw the joint cap firmly into the connection port of the sake meter once more again. (Fig. 17) 5) Carefully keep the joint cap at hand. Dispense the warmed sake. 1) Fit the nozzle (sake outlet) into the mouth of your sake server bottle, lightly push the bottle until the nozzle is straight down, and place the server bottle...
  • Page 14: After Use

    After Use <TSK-110A, 210A, 220A, 420A> Daily maintenance (cleaning of sake passage) 1) Pull out the 1.8-liter sake bottle and drain the internal sake, without fail. • To drain sake, press the “manual switch” and wait until the sake stops coming out.
  • Page 15 <TSK-130A, 230A> Daily maintenance (cleaning of sake passage) (1) Remove the used Cubitaner in the following procedure: • Leave the power switch turned ON. 1) Turn the knob of the valve A to the left and adjust it to the “SHUT” position. Throw the nozzle (sake outlet) down to drain the sake remaining inside.
  • Page 16: After-Sales Service

    After-Sales Service Before Calling a Service Person Before calling a service person, carefully read this manual and check the following. Trouble Check • Is the power cord plug fully pushed into the wall outlet? Sake is not warmed. • Is the sake warming temperature set at OFF? •...
  • Page 17: Specifications

    Specifications ∗ The specifications and part of the appearance are subject to change for improvement without notice. TSK-110A TSK-220A Rating 110-120 V, 220-240 V AC, 50/60 Hz 110-120 V, 220-240 V AC, 50/60 Hz Warming system Electrical (indirect heating) Electrical (indirect heating) Capacity One 1.8-liter bottle (replaceable)
  • Page 18 -16-...
  • Page 19 -17-...
  • Page 20 TAIJI & CO., LTD. 5-3, Higashida-machi, Kawasaki-ku, Kawasaki, 210-0005, Japan Telephone: 044-246-0681 Fax: (044) 222-5857 Printed in Japan...