Combustion air system
Hide thumbs Also See for DuraPlus HTC:

Advertisement

ATTACH FLEx ADAPTER
OVER STOVE AIR INLET
BY USING (4) SCREWS.
SECURE FLEx TO
FLEx ADAPTER BY
USING HOSE CLAMP
PROVIDED.
AIR MUST BE ALLOWED TO
FLOW UNDER COLLAR INTO
CEILING SUPPORT. DO NOT
SEAL OPENINGS BETWEEN
COLLAR AND CEILING
SUPPORT.
8
Figure 9
ATTACH ELBOW TO BRANCH
OF ADAPTER WITH (3) SCREWS
PROVIDED.
ATTACH FLEx TO STOVE
AND ELBOW USING HOSE
CLAMPS PROVIDED
Figure 8
of the Adapter. Additional lengths of CAS
Connector pipe can then be installed using the
screws provided to secure the pipe lengths
(male end up, female end down) (Fig 7). A
Telescoping Length will likely be needed. The
final CAS Connector Pipe section is installed
into the bottom of the CAS Ceiling Support and
secured using (3) 3/8" screws provided.
available to provide adjustment in the
connector pipe. The CAS Telescoping Length
are available in 14"-24", 29"-46", or 40"-68"
sizes. Once the adjustable length is at the
TIGHTEN COLLAR AROUND CHIMNEY
SECTION. SLIDE COLLAR DOWN TO
REST ON TOP OF CEILING SUPPORT.
Figure 10
CAS Telescoping Lengths are