CO
sensor
2
Fitting a CO
higher ventilation levels in the event of high CO
levels can be programmed.

Safety group

The safety group consists of:
The safety group, which is made of brass, consists of a stop valve with an integral
non-return valve, a safety valve and drain cock. It can be installed directly
beneath the hot water tank.

Safety features

During periods with cooling ventilation, hot water in the tank can reach very high
temperatures - up to 80 ºC.
A maximum temperature of up to 60 ºC can be set in the control system to
prevent scalding, but active cooling is then limited.
To make full use of the cooling function, scalding protection should be fitted that
mixes hot water with cold to bring the temperature down.
If a solar panel is used to supplement hot water heating, scalding protection must
be fitted.

Flexible sound damper

To make it easy to service the unit in the future, we recommend that you fit a
flexible connection between the unit and the duct system.
Nilan's flexible sound damper absorbs sounds effectively from both the duct
system and from roof stacks.

Trolley

A trolley makes it possible to lift the unit of the pallet without physical strain.
The same trolley can be moved to wheel the unit around.