....................................................... Week program .................................................... After-heating ....................................................Air humidity ............................................................................................................Air exchange ....................................................Air filter ......................................................Temp. control ....................................................Language ......................................................Alarm list Comfort unit ......................................................Alarm list ......................................................Product data Declaration of compliance ............................................Ecodesign data Comfort 600 ............................................
Always disconnect the power supply to the unit before opening the unit doors, for instance for installation, inspection, cleaning and filter change. Disposal Ventilation unit Nilan’s units consist mainly of recyclable materials. They must, therefore, not be mixed with household waste, but must be delivered to your local recycling center for disposal.
On the right side of the unit you will find the Nilan type plate. Note: Contact Nilan a/s with questions about the product, it is important to have the unit name and serial No. (SN) ready. On the basis of this information, please contact service department find all informations about the relevant aggregate and thus provide information and answer questions about what the aggregate consists of/contains, as well as the software used.
Comfort 600 (English) BY NILAN Quick guide Functions of control panel Main screen elements The main screen of the HMI panel contains the settings options and the information that an operator mostly uses. 1. Shows the current room temperature in the house, measured via the extract air.
Settings options on the main screen The settings options which the user needs in daily life can all be controlled from the main screen of the panel. If you select the option of current room temperature, the desired room temperature will be displayed. The desired room temperature can be adjusted by pressing the up-or-down arrows followed by the cancel icon (bottom left) or the accept icon (bottom right).
Comfort 600 (English) BY NILAN Warnings and alarms Should an error occur in the operation of the unit, a warning or an alarm will be displayed. A warning will be displayed in the top righthand corner in the menu bar.
Maintenance Nilan’s ventilation units last for many years, but to get the best out of them whilst avoiding unnecessary electricity consumption, correct maintenance is important.
Illustration of filter change 1. Before opening the door, switch the unit off on the 2. The screws loosened in the upper cover and pull the control panel under OPERATION. This is situated in the cover lifted out main menu SETTINGS 3.
Comfort 600 (English) BY NILAN Service Annual service It is important to perform an annual service on the unit to ensure it will continue to perform optimally with low energy consumption and long service life. You are recommended to take out a service agreement with the installer, as certain elements of the service require an authorised technician.
User settings Ventilation settings Stop the unit If it is necessary to open the doors while servicing the unit, for instance when changing filters, the unit must be turned off. The functions of the unit are activated in Settings under Operation. If the unit is off, an icon appears on the main screen.
Comfort 600 (English) BY NILAN Alarm You can read warnings and alarms in the "Alarm" menu. It is likewise possible to reset warnings and alarms in this menu. When a warning or an alarm has been triggered, an icon appears on the main screen Alarm ↳...
Show data It is possible to read off relevant data for Comfort units. Show data ↳ Operating state Description: Shows the operating setting in which the unit is running. ↳ Bypass Description: Shows whether the bypass damper is open or closed. ↳...
Comfort 600 (English) BY NILAN Date/Time It is important to set date and time correctly. It makes it easier to localise errors indicated in an error report. When logging data, it is important to be able to follow the history. The time is shown under “Date / Time”...
Week program You can program the unit to run in accordance with specific settings at fixed times during the week via a week program. On the main screen an icon will be displayed when the week program is active Week program ↳...
Comfort 600 (English) BY NILAN ↳ Start time Settings: Hours and minutes Standard setting: 22:00 Description: Set the time for the program to start. The program will run until the next change in the week program. ↳ Ventilation Settings: Level 1 / Level 2 / Level 3 / Level 4 / Off...
Air humidity The primary purpose of ventilation is to extract humidity from the house so it does not damage the building, and to achieve a good indoor climate. During long periods with sub-zero temperatures, air humidity in the house may fall to a level that is critical for the building and for the indoor climate. Wooden floors, furniture and walls can be damaged by very dry air, which also whirls up dust, resulting in a poor indoor climate.
Comfort 600 (English) BY NILAN This menu is only displayed if a CO2 sensor has been installed. sensor. ATTENTION A CO2 sensor is not a standard part of all units, but may be purchased as an accessory. If the number of people using a building varies considerably, controlling ventilation through the CO2 level in the extract air may be a good solution.
Air exchange Low humidity in the dwelling can be prevented by reducing ventilation at low outdoor temperatures. This function can be used in countries with regular sub-zero temperatures and at high altitudes where the outdoor air is very dry. This function can also be used at cold outdoor temperatures if no after-heating element has been installed, and the supply air feels too cold.
Comfort 600 (English) BY NILAN Temp. control The settings are used to control the bypass damper if an after-heating element has not been installed. If you wish to control the supply air temperature, an after-heating element must be installed. An after- heating element allows you to control the supply air temperature, regardless of the outdoor temperature.
Language The unit is factory-set to Danish language. You can change the texts to other languages. Language ↳ Danish Description: Select the desired language on the panel.
Comfort 600 (English) BY NILAN Alarm list Comfort unit Alarm list The first column in the event log shows whether the event relates to master (M) or slave (3). The list below relates to Comfort, and the events are divided into the following categories: Warning Operation continues, but something no longer functions optimally.
Page 24
Reset alarm. Parts of the program setting have been Set the desired week program. lost. Contact service if the unit does not Content of database This may be due to a prolonged power operate to your satisfaction/ as before, changed cut or a lightning strike.
Ecodesign data Comfort 600 Trademark Nilan Model Comfort 600: Bi-directional air handling unit for purposes other than Type housing Type of drive Variable speed drive Type of heat recovery system Counterflow heat exchanger Temperature efficiency 79.6% Reference flow rate 0.1594 m Reference flow rate 0.1404 m...