7.1

Product description

7.2

Mounting and Connection

7.2.1
Mounting and Connection
7.2.2

Connecting the Coaxial Cable

Terminal
S
+
7.2.3

LED

The registration unit 90 00 is equipped with a 2-color, red/green LED. To ensure the visibility of the
LED, the cover in the area of the LED must have a drill hole of Ø 5.2 mm, where you would like visual
as well as acoustic signaling.
The LED is mechanically compatible with registration unit LA-PB solutions
32
PCB 90 00
Meaning
Antenna cable shield wire
Antenna cable inner
conductor
The registration unit 9, together with the control
unit, represents a fully-integrated solution for
access control with simultaneous convenient
identification of the user. The registration unit is
suitable for mounting in on-site assortment of
switches or sockets or in customer-specific
solutions. The new antenna design observes
sufficient distance to the environment and is
therefore also suitable for mounting in a metallic
environment. Owing to the simple cabling,
installation costs are very low.
This registration unit can be simply integrated in
current European standard installation sockets
(size I). The thread insert with thread M3 is
suitable for the mounting of various European
covers.
Suitable Housing / Covers
See Accessories
To ensure the visibility of the LED, the cover in
the area of the LED must have a drill hole of
Ø 5.2 mm.