Ethernet Interface Setup Guide
Setting raw TCP/IP port
ASCII
US BS EOT n1 n2
Hexadecimal
1F 08 04
Decimal
31 8
4
n1:
Low order byte of port #
n2:
High order byte of port #
Default:
Port = 9001
Sets the port where the printer will look for raw TCP/IP communications. Setting port number to 0 disables raw TCP/IP
communications.
DHCP (auto-configuration)
ASCII
US BS BS n1
Hexadecimal
1F 08 08 n1
Decimal
31 8 8
n1 = 0:
disabled
n1 = 1:
enabled
Default:
enabled
Enables or disables the use of DHCP at power-up to obtain an IP address. If no address is found within two minutes,
DHCP obtains the default IP address.

Inactivity timeout

ASCII
US BS HT n1
Hexadecimal
1F 08 09 n1
Decimal
31 8 9
n1 = 0:
disabled
n1 = 1:
enabled
Default:
disabled
Enables or disables resetting of open TCP ports after five (5) minutes inactivity.
Keep alive pings
ASCII
US BS LF n1
Hexadecimal
1F 08 0A n1
Decimal
31 8 10 n1
n1 = 0:
disabled
n1 = 1:
enabled
Default:
disabled
Enables or disables sending of the keep alive pings (self arps). Keep alive pings may be required for use with such things
as smart hubs; to remind the smart hub to which port a printer is connected.
If enabled, self arps are sent every ten (10) minutes.