Schematic Diagram - GE Monogram ZKD910 B Series Technical Service Manual

Electric warming drawer

Advertisement

SERVICEABILITY
To access electrical components
follow the steps listed below:
Ê
Remove Warming
Drawer Pan
Î
Remove right side panel
to access electrical
components & wiring
Proof
75-95° F.
Low
140-160° F.
Med
160-195° F.
High
195-230° F.
With warming pan &
drawer front removed,
remove 4 screws
which secure warming
drawer chassis to
cabinets. Pull chassis
forward to access side
panel
Ì
N
W
HEATING
ELEMENT
W
31W
ON SIGNAL
LIGHT
release levers. Firmly pull
Ë
HEATING
ELEMENT
THERMOSTAT
Î
ON/OFF
SWITCH
LAMP
TEMPERATURE
CONTROL
BK
R
Remove drawer front
by lifting up on side rail
the drawer front away
from the chassis.
RELEASE
LEVER
THERMO.
BULB
Note location of heating
element and thermostat
sensing bulb
HEATING
ELEMENT
LEADS
POWER
CORD
ON/OFF
SWITCH
R

SCHEMATIC DIAGRAM

Í