Failure modes in Current Mode
Failure modes in Current Mode
Failure modes in Current Mode
Failure modes in Current Mode
Failure modes in Current Mode
The table below presents failure modes and effects on I/O.
Failure mode
Failure mode
Failure mode
Failure mode
Failure mode
1
COUT Open
2
RET (active) Open
3
RET (passive) Open
4
COUT Short-circuit to RET (active)
5
COUT Short-circuit to RET (passive)
6
COUT Short-circuit to +BAT
7
COUT Short-circuit to - BAT
8
RET (active) Short-circuit to +BAT
9
RET (active) Short-circuit to - BAT
10
RET (passive) Short-circuit to +BAT
11
RET (passive) Short-circuit to - BAT
12
COUT Short-circuit to 2:nd COUT
(passive)
13
COUT Short-circuit to 2:nd RET(active)
14
COUT Short-circuit to 2:nd RET(passive) Not detected, will not influence function
15
RET Short-circuit to 2:nd RET (active)
16
RET Short-circuit to 2:nd RET (passive)
17
Insufficient Voltage
(a).Turning off outputs are controlled by CAN master and therefore delayed by maximum 2 bus
(a).Turning off outputs are controlled by CAN master and therefore delayed by maximum 2 bus
(a).Turning off outputs are controlled by CAN master and therefore delayed by maximum 2 bus
(a).Turning off outputs are controlled by CAN master and therefore delayed by maximum 2 bus
(a).Turning off outputs are controlled by CAN master and therefore delayed by maximum 2 bus
cycles. If local error handling is enabled the output will turn off locally without delay.
cycles. If local error handling is enabled the output will turn off locally without delay.
cycles. If local error handling is enabled the output will turn off locally without delay.
cycles. If local error handling is enabled the output will turn off locally without delay.
cycles. If local error handling is enabled the output will turn off locally without delay.
(b).Turned off by integrated protection functions in IC.
(b).Turned off by integrated protection functions in IC.
(b).Turned off by integrated protection functions in IC.
(b).Turned off by integrated protection functions in IC.
(b).Turned off by integrated protection functions in IC.
IQAN XA2
IQAN XA2
IQAN XA2
IQAN XA2
IQAN XA2
FAILURE MODE
COUT error, output turned off
COUT error, output turned off
Not detected, will not influence function
COUT error, output turned off (b)
Not detected, will not influence function
COUT error, output turned off
COUT error, output turned off (b)
COUT error, output turned off (b)
COUT error, output turned off
Not detected, will not influence function
COUT error, output turned off
Not detected, will not influence function
COUT error, output turned off (b)
COUT error, output turned off
Not detected, will not influence function
COUT error, output turned off
page 37
page 37
page 37
page 37
page 37
240 Harvester Feller/
Buncher
Effect (a)
Effect (a)
Effect (a)
Effect (a)
Effect (a)