LIGHTING THE PILOT BURNER

STOP: READ THE WARNINGS ABOVE.
This appliance has a pilot burner which must be lit
manually. If the pilot flame has gone out, follow these
instructions exactly.
1. Set the thermostat to its lowest setting.
2. Disconnect all electric power to the appliance.
3. Remove gas control access panel.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
NOTE: Gas control knob can not be turned from PILOT to
OFF unless it is pushed in slightly. Do not force gas
control knob.
5. Wait five minutes to clear out any gas. If you then smell
gas, STOP! Follow "WARNING 3". If you do not smell gas,
continue with next step.
6. Remove the pilot burner access panel located below
and behind the gas control.
7. Find the pilot burner by following the metal tube from
the gas control. The pilot is between the two burner tubes
behind the pilot burner access panel.
8. Turn gas control knob on gas control counterclock-
wise
to PILOT.
9. Push in gas control knob all the way and hold in.
Immediately light the pilot flame with a match and continue
holding the gas control knob in for one minute after the pilot
flame is lit.
10.Release gas control knob and it will pop back up. Pilot
flame should remain lit. If pilot flame goes out, repeat steps
1 through 10.
• If gas control knob does not pop up when released,
stop and immediately and call your service technician
or gas supplier.
• If the pilot flame will not stay lit after several tries, turn
the gas control knob to OFF and call your service
technician or gas supplier.
11. Turn gas control knob counterclockwise
ON.
12. Replace pilot burner access panel.
13. Replace gas control access panel.
14. Reconnect all electric power to the appliance.
15. Set thermostat to desired setting.

TURNING OFF THE APPLIANCE

VACATION SHUTDOWN—Set thermostat to desired room
temperature while you are away.
COMPLETE SHUTDOWN—Push in gas control knob
slightly and turn clockwise
Appliance will completely shut off. Follow lighting proce-
dures above to resume normal operation.