Fibre Channel Connections - Fujitsu ETERNUS LT140 User Manual

Tape library, server connection
Hide thumbs Also See for ETERNUS LT140:
Table of Contents

Advertisement

Chapter 3 Setting the Operating System
3.3 Windows
3.3.2

Fibre Channel Connections

This section explains how to set up the server to connect the tape library by using a Fibre Channel connection.
(1) Install the driver and set up the Fibre Channel card.
For details about how to install the driver and set up the Fibre Channel card, refer to the manual that is
provided with each Fibre Channel card.
Fixing the target ID
The target ID is assigned to a device which connects to the Fibre Channel card. By default, the target ID is
automatically set by the driver. Therefore, the assigned target ID of the device may be changed when
adding or removing devices. It may also be changed based on the state in which the device is recognized.
If the target ID is different before and after rebooting the server, depending on the OS and application,
the device may go off-line and become unavailable. To avoid this, setting the fixed target ID to each
device is recommended.
(2) Check the devices.
Procedure
1
Open [Device Manager] from [Control Panel].
2
Change [View] of [Device Manager] to [Device (by Connection)].
3
Confirm that "IBM UltriumX SCSI Sequential Device" or "Unknown Medium Changer Device"
(controller) are displayed for the HBA that is connected to the LT140.
"UltriumX" shows the drive type. For example, "Ultrium7" is displayed for LTO7 drives and "Ultrium8"
is displayed for LTO8 drives.
The "?" icon may be displayed for "HP UltriumX SCSI Sequential Device" or "IBM UltriumX SCSI
Sequential Device". In this situation, the LTO drive is not recognized due to the backup software or
the version of the backup software used. To solve this problem, reinstall the driver using the proce-
dure indicated in
After the contents in
If the above contents cannot be checked, check again whether the HBA driver has been successfully
installed. If no problem is found with the installation of the HBA driver, a powered-off LT140, loose
connection, or a setting error of topology/Loop ID can be assumed. Check the settings and reboot the
server before considering the contents.
FUJITSU Storage ETERNUS LT140 Tape Library User's Guide -Server Connection-
"3.3.4 Installing a Driver" (page
Step 3
are checked in the Device Manager, the connection test is complete.
30
Copyright 2019 FUJITSU LIMITED
33).
End of procedure