Installer Setting - Thermistor - LG UB85W.N94R0 Installation Manual

Ceiling concealed duct
Table of Contents

Advertisement

Installer Setting - Thermistor

This is the function to select the temperature sensor to judge the room temperature.
<Thermistor Table>
Temperature sensor selection
01 Remote controller
02 Indoor unit
Cooling
03 2TH
Heating
j The function of 2TH has different operation characteristics according to the product.
If pressing
1
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
If moving to room temperature perception
2
sensor selection menu by pressing
button, it indicates as picture below.
Set Thermistor value by pressing
3
button. (01: Remote Controller,
02: Indoor, 03: 2TH)
Function Code
4
Press
Pressing
5
❈ After setup, it automatically gets out of
❈ When exiting without pressing set button,
Function
Operation in remote controller temperature sensor
Operation in indoor unit temperature sensor
Operation of higher temperature by comparing indoor unit's and wired
remote controller's temperature.
(There are products that operate at a lower temperature.)
Operation of lower temperature by comparing indoor unit's and wired
remote controller's temperature.
button long for 3
into user setup mode. Please press
more than 3 seconds for sure.
Thermistor setting
button to save.
button will exit settings mode.
setup mode if there is no button input for
25 seconds.
the manipulated value is not reflected.
Optional Operation
Installation Manual 19

Hide quick links: