Selecting The Installation Location; Installation Work - Fujitsu ASU30RLE Installation Manual

Indoor unit
Hide thumbs Also See for ASU30RLE:
Table of Contents

Advertisement

Install heat insulation around both the gas and liquid pipes. Failure to do so may
cause ater lea s.
Use heat insulation ith heat resistance above 248 F (120 C). Reverse cycle model
only.
In addition, if the humidity level at the installation location of the refrigerant piping
is e pected to e ceed 70 , install heat insulation around the refrigerant piping. If
the e pected humidity level is 70-80 , use heat insulation that is 3/4 in. (15 mm) or
thic er and if the e pected humidity e ceeds 80 , use heat insulation that is 13/16 in.
(20 mm) or thic er.
If heat insulation is used that is not as thic as speci ed, condensation may form on
the surface of the insulation. In addition, use heat insulation ith heat conductivity of
0.045 W/(m K) or less (at 68 F (20 C) ).
3.2. Electrical requirement
The indoor unit is po ered from the outdoor unit or branch bo . Do not po er indoor unit
from separate po er source.
Refer to local codes for acceptable cable type.

4. SELECTING THE INSTALLATION LOCATION

Decide the mounting position ith the customer as follo s
(1) Install the indoor unit level on a strong all hich is not subject to vibration.
(2) The inlet and outlet ports should not be obstructed the air should be able to blo all
over the room.
(3) Install the unit a dedicated electrical branch circuit.
(4) Do not install the unit here it ill be e posed to direct sunlight.
(5) Install the unit here connection to the outdoor unit or branch bo is easy.
(6) Install the unit here the drain pipe can be easily installed.
(7) Ta e servicing, etc. into consideration and leave the spaces sho n in 5.1. Installation
dimensions . Also install the unit here the lter can be removed.
Correct initial installation location is important because it is dif cult to move unit after it is
installed.
Install the air conditioner in a location hich can ithstand a load of at least 3 times the
eight of the main unit and hich ill not amplify sound or vibration. If the installation
location is not strong enough, the indoor unit may fall and cause injuries.
Withstandable eight (Unit eight
120 Lbs (54 g)
Do not install the unit in the follo ing areas
Area ith high salt content, such as at the seaside. It ill deteriorate metal parts, caus-
ing the parts to fail or the unit to lea
Area lled ith mineral oil or containing a large amount of splashed oil or steam, such
as a itchen.
It ill deteriorate plastic parts, causing the parts to fail or the unit to lea
Area that generates substances that adversely affect the equipment, such as sulfuric
gas, chlorine gas, acid, or al ali.
It ill cause the copper pipes and brazed joints to corrode, hich can cause refrigerant
lea age.
Area that can cause combustible gas to lea , contains suspended carbon bers or
ammable dust, or volatile in ammables such as paint thinner or gasoline.
If gas lea s and settles around the unit, it can cause a re.
Area here animals may urinate on the unit or ammonia may be generated.
Do not use the unit for special purposes, such as storing food, raising animals, gro -
ing plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.
Do not install here there is the arning of combustible gas lea age.
Do not install the unit near a source of heat, steam, or ammable gas.
Install the unit here drainage does not cause any trouble.
Install the indoor unit, outdoor unit, branch bo , po er supply cable, transmission
cable, and remote controller cable at least 40 in. (1m) a ay from a television or radio
receivers. The purpose of this is to prevent TV reception interference or radio noise.
(Even if they are installed more than 40 in. (1m) apart, you could still receive noise
under some signal conditions.)
If children under 10 years old may approach the unit, ta e preventive measures so
that they cannot reach the unit.
Install the indoor unit on the
all
(1.8 m).
CAUTION
WARNING
WARNING
3 )
In accordance ith UL standards.
CAUTION
ater.
ater.
here the height from the oors more than 70 in.

5. INSTALLATION WORK

Do not hit or push the human sensor. This may lead to damage or malfunction.
Do not touch the human sensor. Any scratches or dirt may lead to incorrect detection.
Do not place large objects near the human sensor. Also eep heating units outside
the sensor s detection area.
Detection range of the human sensor is as follo s.
Vertical angle 90 (Side vie )
22ft (7m)
90°
5.1. Installation dimensions
3 (80) or over
2-3/8 (60) or over
59 (1.5 m)
or over
70 (1.8 m) or over
Remote
controller
Remote
controller
holder
Tapping scre
(small)
5.2. Indoor unit piping direction
The piping can be connected in the 6 directions indicated in the follo ing.
When the piping is connected to direction (B) , (C) , (D) or (E) , cut along the piping groove
on the side of the front cover ith a hac sa .
(B) Right
outlet
(A) Rear
outlet
(C) Bottom
outlet
5.3. Cutting the hole in the wall for the connecting piping
(1) Cut a 80 mm diameter hole in the all at the position sho n in the follo ing.
(2) Cut the hole so that the outside end is lo er (5 to 10 mm) than the inside end.
(3) Al ays align the center of the all hole. If misaligned, ater lea age ill occur.
(4) Cut the all pipe to match the all thic ness, stic it into the all cap, fasten the cap ith
vinyl tape, and stic the pipe through the hole.
(5) For left piping and right piping, cut the hole a little lo er so that drain
freely.
Wall hoo brac et
Lo er
80 mm hole
10 mm
or more
Fasten ith
vinyl tape
Wall pipe
(Inside)
Wall cap
Al ays use the all pipe. If the all pipe is not used, the cable that is connected bet een
the indoor unit and the outdoor unit may touch metal, and cause an electric discharge.
CAUTION
Horizontal angle 100 (Top vie )
22ft
(7m)
50°
50°
Wall hoo brac et
5-1/8 (130) or
over
Unit in. (mm)
(Wall cap)
The distance bet een the all hoo
brac et and the ceiling should be
3 in (80 mm) or more.
The side ne t to the side all must
follo the size indicated in figure.
(Rear)
(E) Left
outlet
(G) Left rear
outlet
(F) Centre
outlet
(D) Left bottom
outlet
ater
Centring mar s
80 mm hole
10 mm
or more
5 to 10 mm lo
(Outside)
Locally purchased
Wall
WARNING
ill o
Lo er
En-3