11.2.2
Number of Bytes in Serial Number
The up and down arrows let you add or delete bytes for the serial number,
max=10 hex (16 base ten), min=1.
11.2.3
Count Sequence
This window lets you count up or down through the sequencing of the serial
number. The serial number is allowed to wrap over the top of the highest
serial number or below the lowest serial number. Note that in P&E
programmers, the serial number can only count up and any attempt to
overflow will cause an error.
11.2.4
Serial Number Bytes as Hex
There is one display column for each byte in the serial number shown as
printable ASCII characters. Non-printable ASCII characters are indicated by
the small solid block graphic.
11.2.5
Hex Upper Bounds
There is one display column for each upper bound of the byte in the serial
number in hex.
Cyclone for STMicro - User Manual
choose from existing files by disk, directory, name, and extension.
Up Arrow Click - Adds new bytes to the Serial Number. Each byte
added appears as a new column in the serial number representation.
Added bytes are input as Binary Bytes, i.e. the upper bound is FF and
the lower bound is 00.
Down Arrow Click - Deletes bytes from the right end of the Serial
Number. Any previously entered byte properties are lost.
Up Arrow Click - Counts the serial number up.
Down Arrow Click - Counts the serial number down.
Up Arrow Click - Counts the serial number up.
Down Arrow Click - Counts the serial number down.
Up Arrow Click - Increases the upper bound by one with a maximum
of FF Hex.
Down Arrow Click - Decreases the upper bound by one with a
minimum of the current serial number byte value.