Safety
Notes
Gloves
should
be
worn
during
installation
to
prevent
crushing
and
cutting
injuries.
The
arm
of
the
shower
head
is
intended
only
to
hold
the
shower
head.
Do
not
load
it
down
with
other
objects!
Children
as
well
as
adults
with
physical,
mental
and/or
sensoric
impairments
must
not
use
this
product
without
proper
supervision.
Persons
under
the
influ-
ence
of
alcohol
or
drugs
are
prohibited
from
using
this
product.
Do
not
allow
the
streams
of
the
shower
touch
sensitive
body
parts
(such
as
your
eyes).
An
adequate
distance
must
be
kept
between
the
shower
and
you.
The
product
may
not
be
used
as
a
holding
handle.
A
separate
handle
must
be
installed.
The
shower
system
may
only
be
used
for
bathing,
hygienic
and
body
cleaning
purposes.
The
hot
and
cold
supplies
must
be
of
equal
pressures.
Installation
Instructions
•
Prior
to
installation,
inspect
the
product
for
transport
damages.
After
it
has
been
installed,
no
transport
or
surface
damage
will
be
honoured.
•
The
pipes
and
the
fixture
must
be
installed,
flushed
and
tested
as
per
the
applica-
ble
standards.
•
The
plumbing
codes
applicable
in
the
respective
countries
must
be
oberserved.
•
The
installation
dimensions
stated
in
these
installation
instructions
are
ideal
for
people
of
approximately
1800
mm
in
body
height.
The
dimensions
can
be
altered
if
required.
In
this
case,
pay
attention
to
the
fact
that
a
change
of
instal-
lation
height
will
also
change
the
minimum
height,
and
that
the
altered
mounting
dimensions
must
be
taken
into
consideration.
•
Where
the
contractor
mounts
the
product,
he
should
ensure
that
the
entire
area
of
the
wall
to
which
the
mounting
plate
is
to
be
fitted,
is
flat
(no
projecting
joints
or
tiles
sticking
out),
that
the
structure
of
the
wall
is
suitable
for
the
installation
of
the
product
and
has
no
weak
points.
The
enclosed
screws
and
dowels
are
only
suit-
able
for
concrete.
For
another
wall
constructions
the
manufacturer's
indications
of
the
dowel
manufacturer
have
to
be
taken
into
account.
•
The
mesh
washer
must
be
insert
to
protect
the
overhead
shower
against
incoming
dirt
by
pipework.
Incoming
dirt
leads
to
defects
or/and
can
damage
parts
of
the
shower;
such
caused
faults
voids
all
liability
and
guarantee
claims.
•
The
product
is
not
designed
to
be
used
with
steam
baths!
•
If
the
continuous
water
heater
causes
any
problems,
or
you
have
different
water
pressures
you
must
install
a
water
limiter
to
the
cold
supply,
(ordered
separately,article
number
97510000).
•
If
required,
the
bottom
part
of
the
pipe
between
the
fixture
and
the
shower
head
can
be
shortened
with
a
fine-toothed
saw.
Fault
Insufficient
water
Crossflow,
hot
water
being
forced
into
cold
water
pipe,
or
vice
versa,
when
mixer
is
closed
Spout
temperature
does
not
correspond
with
tempera-
ture
set
Temperature
regulation
not
possible
Instantaneous
heater
didn't
work
with
thermostat
2
English
Technical
Data
Operating
pressure:
Recommended
operating
pressure:
Test
pressure:
(1
MPa
=
10
bar
=
147
PSI)
Hot
water
temperature:
Recommended
hot
water
temp.:
Centre
distance:
Connections
G1/2:
Thermal
disinfection:
Safety
against
backflow
The
product
is
exclusively
designed
for
drinking
water!
Symbol
description
Cause
-
Supply
pressure
inadequate
-
Filters
are
dirty
(#96922000)
-
Shower
filter
seal
dirty
-
Backflow
preventers
dirty
or
leaking
-
Thermostat
has
not
been
adjusted
-
Hot
water
temperature
too
low
-
thermo
cartridge
calcified
-
Filters
are
dirty
-
check
valve
hasn't
moved
back
Assembly
see
page
4
Do
not
use
silicone
containing
acetic
acid!
Safety
Function
(see
page
6)
The
desired
maximum
temperature
for
example
max.
42º
C
can
be
pre-
set
thanks
to
the
safety
function.
Adjustment
(see
page
6)
After
the
installation,
the
output
temperature
of
the
thermostat
must
be
checked.
A
correction
is
necessary
if
the
temperature
measured
at
the
output
differs
from
the
temperature
set
on
the
thermostat.
Maintenance
(see
page
9)
•
To
guarantee
the
smooth
running
of
the
thermostat,
it
is
necessary
from
time
to
time
to
turn
the
thermostat
from
total
hot
to
total
cold.
•
The
mixer
is
equipped
with
check
valves.
The
check
valves
must
be
checked
regularly
according
to
DIN
EN
1717
in
accordance
with
national
or
regional
regulations
(at
least
once
a
year).
Dimensions
(see
page
8)
Flow
diagram
(see
page
8)
overhead
shower
Hand
shower
Operation
(see
page
9)
Cleaning
(see
page
9)
Spare
parts
(see
page
11)
Special
accessories
(order
as
an
extra)
tile-matching-disk
chrome
plated
#95163000
(see
page
11)
Remedy
-
Check
water
pressure
(If
a
pump
has
been
installed
check
to
see
if
the
pump
is
working).
-
Clean
filter
in
front
of
the
mixer
and
on
the
MTC-
thermo
cartridge
(#96922000)
-
Clean
filter
seal
between
shower
and
hose
-
Clean
backflow
preventers,
exchange
if
necessary
-
Adjust
thermostat
-
Increase
hot
water
temperature
to
42
ºC
to
65
ºC
-
Exchange
thermo
cartridge
-
Clean
the
filter
/
exchange
filter
-
Exchange
check
valves
max.
1
MPa
0,1
-
0,5
MPa
1,6
MPa
max.
70°C
65°C
150
±
12mm
cold
right
-
hot
left
max.
70°C
/
4
min