IDEAL PRO Series Installation And Servicing page 17

Table of Contents

Advertisement

(S-PLAN) WIRING DIAGRAM WITH TWO 2 PORT VALVES AND BOILER CONTROLLED PUMP OVERRUN OPTION
HW
Central Heating Control
OFF
ON
ELECTRONICS
N
L
1
2
Bl
Br
Br
Bl
G/Y
Danfoss
WB12
1
2
3
Wiring
Centre
Br
Bl
G/Y
N
E
L
5 Amps
L
N
Mains Supply
Fed Via Double
Pole Isolator
230 VAC ~ 5 Amps
Typical schematic wiring diagram for an unvented installation
(Y-PLAN) WIRING DIAGRAM WITH 3 PORT VALVE/2 PORT SAFETY VALVE AND BOILER CONTROLLED PUMP OVERRUN OPTION
HW
Central Heating Control
OFF
ELECTRONICS
N
L
1
Bl
Br
Br
Bl
1
2
Br
Bl
N
L
5 Amps
L
N
Mains Supply
Fed Via Double
Pole Isolator
230 VAC ~ 5 Amps
CH
Room Thermostat
OFF
ON
1
2
3
3
4
G/Y
Br
Bl
B
4 core cable
Br
Br
Br
Br
B
*Br
G/Y
Bl
4
5
6
7
8
9
10
Or
Br
Br
Bl
G/Y
Gr
HW
HTG
VALVE
VALVE
Br
Bl G/Y
Gr
Or
Br
V4043A
V4043A
TWO PORT
TWO PORT
ZONE VALVE
ZONE VALVE
HTG
B
A
A
CH
Room Thermostat
ON
OFF
ON
1
2
3
4
G/Y
Br
Bl
Br
Br
G/Y
Br
Br
B
*Br
G/Y
Bl
3
4
5
6
7
8
9
Gr
G/Y
Wh
Br
Bl
G/Y
E
HW
HTG
VALVE
VALVE
Wh
Bl G/Y
Gr
Or
V4073A
MID POSITION
ZONE VALVE
HTG
B
A
Typical schematic wiring diagram for an unvented installation
Page 17
INSTALLATION
Dual Cylinder Stat
Spade
connectors
Overheat Stat
required
for earth
connections
1
C
2
4
R (Supplied with stat)
G/Y
Br
4 core cable
B
Br
B
Or
Br
* Blue core used
from standard 3 core
Provide extra core
12
11
flex please ensure you
from terminal 12 to
use brown sleeving at
L-P connection on
both terminating ends
the boiler (shown
to identify core potential.
dotted) and remove
the boiler pump link
if the boiler has an
independant
pump output.
Br
Bl
G/Y
Bl G/Y Or Gr
L
N
E
Boiler
DHW
B
Br
Pump
DRN.
N. Fursman
Dual Cylinder Stat
Spade
connectors
Overheat Stat
required
for earth
connections
C
2
1
2
3
4
R (Supplied with stat)
B
G/Y
Br
4 core cable
4 core cable
B
Or
Br
B
Provide extra core
10
13
11
12
from terminal 12 to
L-P connection on
the boiler (shown
dotted) and remove
Or
B
Gr
Br
the boiler pump link
if the boiler has an
independant
pump output.
Br
Bl
Br
Bl G/Y Or Gr
L
V4043A
TWO PORT
ZONE VALVE
Boiler
DHW
A
B
Pump
DRN.
N. Fursman
WIRE COLOUR LEGEND
R
Red
Bl
Blue
Control Stat
Br
Brown
B
Black
Or
Orange
1
C
2
Y
Yellow
Wh
White
G/Y
Green / Yellow
B
*Br
Gr
Grey
G
Green
The electrical installation must
comply with IEE requirements.
For electrical installation
refer to BS7671
Note: Do not attempt
the electrical work unless
you are competent to carry
out to the above standard
GAS BOILER
Bl G/Y
B
Br
Bl G/Y
DATE
APPROVED
07-12-10
ISSUE No : 5
WIRE COLOUR LEGEND
R
Red
Bl
Blue
Control Stat
Br
Brown
B
Black
Or
Orange
C
2
1
Y
Yellow
Wh
White
G/Y
Green / Yellow
B
*Br
Gr
Grey
G
Green
The electrical installation must
comply with IEE requirements.
For electrical installation
* Blue core used
refer to BS7671
from standard 3 core
flex please ensure you
use brown sleeving at
both terminating ends
to identify core potential.
Note: Do not attempt
the electrical work unless
you are competent to carry
out to the above standard
GAS BOILER
G/Y
N
E
Br
Bl G/Y
B
Br
Bl G/Y
DATE
APPROVED
07-12-10
ISSUE No : 4
INSTALLATION