SPECIFICATION AND INSTALLATION GUIDE
FCR2
Field Cut Riser System
For Use with Grease Interceptors Models GB-500,
GB-1000, GGI-750, GGI-1000 and GGI-1500
Contents
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Special Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Getting to Know the FCR2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Notes
1.
Unit weight: 32 lbs.
2. Riser not designed to hold water
Engineer Specification Guide:
Field-cut adjustable riser system to consist of injection molded polypropylene
body, 100% Silicone Sealant for assembly of riser components, butyl mastic sealant
for tank-riser or riser-riser joints, stainless steel fastening hardware and heavy duty
nylon cable ties and mounts. Riser shall allow field adjustability of cover to grade.
Installation Note
Minimum install height: 4". Maximum install height: 34". Riser system may be
stacked no more than three units high to a maximum of 94" extension. Access to
internal components will not be compromised.
9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | www.schierproducts.com
MODEL NUMBER:
FCR2
PART #: 8010-006-01
DWG BY: B. Karrer
TOP VIEW
SIDE VIEW
1" TYP
Cut
Lines
SECTION A-A
1"
Riser Height Needed
0" - 4"
>4" - 34"
>34" - 64"
>64" - 94"
DESCRIPTION: 34" Field Cut Riser System
DATE: 9/3/2019
A
6" TYP
A
ø 27-1/2"
ø 23"
32-1/2"
ø 24-3/16"
Risers Required
(per accessway)
None (use adapter)
FCR2
FCR2 (x2)
FCR2 (x3)
REV:
ECO:
© Copyright 2019 Schier, All Rights Reserved