Machine
Function and input
parameter
MP4131
Criterion for activating the fast PLC input
from MP4130
Input:
MP4131.0
Fast PLC input for switching off the
monitoring functions
MP4131.1
No function
MP4131.2
Fast PLC input for sets M4590
(signal duration > 6 ms)
MP4131.3
Fast PLC input sets M4591
(signal duration > 6 ms)
MP4131.4
Fast PLC input sets M4592
(signal duration > 6 ms)
MP4131.5
Fast PLC input sets M4593
(signal duration > 6 ms)
MP4210.0-47 Setting a number in the PLC (D768 to
D956)
Input: –30 000.000 to +30 000.000 [mm]
MP4220.0-3
Setting a number in the PLC (Word range
W960 to W968)
Input: 0 to 65 535
MP4230.0-31 Setting a number in the PLC (Module
9032)
Input: –99 999.999 to +99 999.999
MP4231.0-31 Setting a number in the PLC (Module
9032)
Input: –99 999.999 to +99 999.999
MP4310.0-6
Setting a number in the PLC
(W976 to W988)
Input: 0 to 65 535
July 02
0 = Activation at Low level
1 = Activation at High level
$0000 to $FFFF