5. INSTALLATION AND SETUP
Installation of the CC-8551AN Crypto
Lock consists of mounting the Keypad and
Control Unit, connecting the Keypad cable,
power cord, external lock and other
devices and installing the batteries
(optional). Setup includes setting switches
to determine the lock voltage and current
limits and setting the PIN code length and
digits.
A. INSTALLATION
1) Mount the Keypad approximately 36 to
44 inches above the floor on the unsecured
side of the door.
2) Mount the electric lock, strike or magnet
according to the manufacturer's
instructions.
3) Mount the Control Unit on the secure
side of door in an area convenient to the
door and an electrical outlet.
4) If required, install the supplied Cam
Lock in the knockout hole provided for that
purpose on the enclosure door.
Alternatively, if a padlock (not supplied) is
to be used remove the two 3/8" nylon plugs
from the padlock holes. The padlock's
shackle must be first inserted through the
hole on the side of the enclosure, then the
door can be closed so that the padlock hole
on the door also passes over the shackle. If
the door does not need to be locked, two
screws can be used in the door edge holes
to hold it closed.
5) Connect the Keypad to the Control Unit
by number as shown in Figure 3. Twenty
feet of cable is supplied with the Keypad.
The Keypad can be located up to 200 feet
from Control Unit using additional cable.
(Requires 14 conductors, #22).
6) Connect the electric lock, strike or
magnet as shown in Figure 3.
7) May connect a Release Button
(not supplied), and external 12VDC
annunciator (not supplied), as shown in
Figure 3. Note that an internal annunciator
on the Logic Board will sound when the
Keypad's annunciator button is pressed.
8) Install and connect the optional batteries
as shown in Figure 3 using the two
supplied battery cables. Use only 12V, 1.2
to 7AH rechargeable sealed lead acid
batteries.
9) Connect the AC Power Cord to
Terminal T4 in accordance with the
available voltage (115 or 230Vac) as
shown in Figure 3.
10) Connect the transformer primary
wires to Terminal T3 in accordance with
the available voltage (115 or 230 Vac) as
shown in Figure 3. CAUTION! The
Control Unit is shipped from the factory
wired for 115 Vac operation. Refer to
Figure 3.
9
Need help?
Do you have a question about the CRYPTO-LOCK CC-8521AN and is the answer not in the manual?
Questions and answers