Daewoo DW-5014 Service Manual page 16

Table of Contents

Advertisement

Problem
There are strange
noise and severe
vibration during
spinning.
There is leakage
during spin drying.
S pin Dryer does
not stop with the
Door Spin *O
open.
Concerning Drainage
Problem
Drainage is not
satisfactory.
Check Point
YES
Is the Bellows Assembly properly
assembled?
YES
Does the Brake Band touches the Drum
coupling when the Door Spin *O open.
YES
Is the electric connection of the Door
Switch good?
YES
Check Point
Is the height of the drainage area where
the Drain Hose hangs over 1m?
(pump model)
NO
Are there impurities in the Drain Strainer?
NO
Are there impurities in the case valve or
Inlet Joint.
NO
Cause
The W aterseal or the Oilless metal in the
Bellows Assembly worn out.
NO
W aterproofing not working
due to defective assem bly.
The waterseal or the oilless
m etal in the Bellows
Assem bly is worn out.
NO
Brake wire is too short
Brake Band is worn out.
NO
Defecive Door Switch
The contact of the Door
switch does not open due
to deformity of the Lever
of Door Switch.
Cause
YES
The Drain Hose is too High.
YES
Impurities are obstructing
drainage.
YES
Impurities are obstructing
drainage.
Impurities are blocking the
Drain Hose.
14
Solution
Replace Bellows Assem bly
Re-assem ble Bellows
Assembly.
Replace Bellows Assembly.
Assemble after loosening
Link Brake and adjusting
upward.
Replace Brake Band or
Brake Fix Assembly.
Replace Door Switch
Replace Door Switch or
reshape the Lever of
Door Switch.
Solution
Hang the Drain Hose lower
Disassemble Pulsator and
take out impurities in Drain
strainer
Remove impurities or
replace Case Valve or
inlet joint.
Remove impurities

Hide quick links: